Recalibration Process<br />

http://www.<strong>image2output</strong>.com<br />

Step 1: Linearization<br />

Recalibration<br />

Recalibration Process<br />

The Recalibration Wizard will guide you through the following steps:<br />

1. Select the measurement device connected to your computer.<br />

We recommend to use the same measurement device that was used<br />

when the printer was linearized and calibrated for the first time.<br />

2. Print the linearization test chart.<br />

3. Measure the printed test chart. You can measure density values or<br />

Lab values. The densitometric method is explained below.<br />

Lab values are measured if the LINEARIZATION option is set to CIE LAB<br />

BASED. Otherwise density values are measured. To set this option,<br />

select FILE | PREFERENCES and click on the GENERAL tab.<br />

4. Optimize the linearization file, if required. The density measurements<br />

should not deviate from the target values by more than 0.02 units.<br />

Fig. 19-3 ‘Linearization by Densities’ Dialog<br />

ORIS <strong>Press</strong> <strong>Matcher</strong>⁄⁄<strong>Web</strong> Version 1.1 Advanced <strong>User</strong>’s <strong>Manual</strong> 19-3<br />