INSTALLATION<br />

Table 3.3 – Recommended cables for connection within the motor delta connection (100%IN)<br />

Type<br />

SSW-03<br />

Plus (A)<br />

120<br />

170<br />

205<br />

255<br />

290<br />

340<br />

410<br />

475<br />

580<br />

670<br />

800<br />

950<br />

Rated<br />

Current<br />

100% (A)<br />

208<br />

294<br />

355<br />

441<br />

502<br />

588<br />

709<br />

822<br />

1003<br />

1159<br />

1384<br />

1644<br />

Connection within motor delta connection<br />

Line<br />

Cables<br />

(mm 2 )<br />

95<br />

150<br />

185<br />

300<br />

2 x 120<br />

2 x 150<br />

2 x 185<br />

2 x 240<br />

4 x 120<br />

4 x 150<br />

4 x 185<br />

4 x 240<br />

Copper cables with PVC 70°C (158°F) isolation, with ambient<br />

temperature of 40°C (104°F) installed in perforated conduits<br />

and not bunched. Non insulated or silver plated bus bars with<br />

rounded edges with 1 mm radius with ambient temperature<br />

of 40°C (104°F) and bus temperature of 80°C (175°F). For correct<br />

cable dimensioning, consider the installation conditions<br />

and the max. permitted voltage drop.<br />

Line<br />

bus<br />

mm x mm<br />

20 x 3<br />

25 x 5<br />

25 x 5<br />

30 x 5<br />

40 x 5<br />

40 x 10<br />

40 x 10<br />

40 x 10<br />

50 x 10<br />

60 x 10<br />

80 x 10<br />

100 x 10<br />

Motor<br />

Cables<br />

(mm 2 )<br />

35<br />

70<br />

95<br />

120<br />

150<br />

185<br />

240<br />

300<br />

2 x 150<br />

2 x 185<br />

2 x 240<br />

2 x 300<br />

Motor<br />

bus<br />

mm x mm<br />

12 x 2<br />

20 x 3<br />

20 x 3<br />

25 x 5<br />

25 x 5<br />

25 x 5<br />

30 x 5<br />

40 x 5<br />

40 x 5<br />

40 x 10<br />

40 x 10<br />

50 x 10<br />

Grounding<br />

Cables<br />

(mm²)<br />

25<br />

35<br />

50<br />

70<br />

95<br />

95<br />

120<br />

150<br />

150<br />

185<br />

240<br />

300<br />

Table 3.4 – Recommended cables for connection within the motor delta connection (120%IN)<br />

Type<br />

SSW-03<br />

Plus (A)<br />

120<br />

170<br />

205<br />

255<br />

290<br />

340<br />

410<br />

475<br />

580<br />

670<br />

800<br />

950<br />

Rated<br />

Current<br />

120% (A)<br />

249<br />

353<br />

426<br />

529<br />

602<br />

706<br />

851<br />

986<br />

1204<br />

1391<br />

1661<br />

1972<br />

Connection within the motor delta Connection<br />

Line<br />

cables<br />

(mm 2 )<br />

120<br />

185<br />

300<br />

2 x 120<br />

2 x 150<br />

2 x 185<br />

2 x 300<br />

4 x 120<br />

4 x 150<br />

4 x 185<br />

4 x 240<br />

-<br />

Line<br />

bus<br />

mm x mm<br />

20 x 3<br />

25 x 5<br />

30 x 5<br />

40 x 5<br />

40 x 10<br />

40 x 10<br />

40 x 10<br />

50 x 10<br />

80 x 10<br />

80 x 10<br />

100 x 10<br />

120 x 10<br />

Motor<br />

Cables<br />

(mm 2 )<br />

50<br />

95<br />

120<br />

150<br />

185<br />

240<br />

2 x120<br />

2 x 150<br />

2 x 185<br />

2 x 240<br />

2 x 300<br />

4 x 150<br />

Motor<br />

bus<br />

mm x mm<br />

20 x 3<br />

20 x 3<br />

20 x 3<br />

25 x 5<br />

25 x 5<br />

30 x 5<br />

40 x 5<br />

40 x 5<br />

40 x 10<br />

40 x 10<br />

50 x 10<br />

60 x 10<br />

Grounding<br />

Cables<br />

(mm²)<br />

25<br />

35<br />

50<br />

70<br />

95<br />

95<br />

120<br />

150<br />

150<br />

185<br />

240<br />

300<br />

29<br />