6<br />

DETAILED PARAMETER DESCRIPTION<br />

6.3.16 - P35 - DC-Braking<br />

voltage level<br />

(%UN)<br />

This parameter sets the AC line voltage, that is converted<br />

directly into DC voltage and applied on the motor<br />

terminals during the braking time.<br />

P35 - DC braking voltage level (% )<br />

min. Range max.<br />

shortest step<br />

Factory<br />

Standard<br />

30% 1% 50% 30<br />

6.3.17 -P36 - Time<br />

interval<br />

between starts<br />

This protection acts limiting the time interval between<br />

starts to avoid excessive starting and stopping conform<br />

time adjusted in parameter P36.<br />

P36 - Time interval between starts<br />

min. Range max.<br />

Shortest step<br />

Factory<br />

Standard<br />

OFF, 1s 1s 999s 2s<br />

Operation by HMI (I/O)<br />

Operation by three wire digital input<br />

(DI1 and DI2)<br />

Attention:<br />

The SSW controller will not accept a new Start command during the time, adjusted in P36, elapses<br />

after Stop. Identically to serial interface communication.<br />