Shear – unstiffened beams<br />

LRFD – E = 29,000 ksi<br />

φ = 0.90 Aw = d tw<br />

h 417<br />

≤ φVn = φ (0.6 Fy) Aw<br />

t F<br />

w<br />

417<br />

F<br />

y<br />

523<br />

F<br />

<<br />

w<br />

y<br />

h<br />

t<br />

≤<br />

523<br />

F<br />

y<br />

⎡<br />

φVn = φ (0.6 Fy) Aw ⎢<br />

417<br />

⎢(<br />

h/t<br />

⎣ w ) F<br />

y<br />

<<br />

COLUMNS<br />

h<br />

t<br />

w<br />

≤ 260<br />

⎡ 218,<br />

000<br />

φVn = φ (0.6 Fy) Aw ⎢<br />

2<br />

⎢⎣<br />

( h/t w ) F<br />

Column effective length KL:<br />

y<br />

y<br />

⎤<br />

⎥<br />

⎥<br />

⎦<br />

⎤<br />

⎥<br />

⎥⎦<br />

123<br />

For<br />

For<br />

w<br />

y<br />

ASD<br />

h 380<br />

≤ : Fv = 0.40 Fy<br />

t F<br />

h 380 Fy<br />

> : Fv = ( Cv<br />

) ≤ 0.4 Fy<br />

t F 2.<br />

89<br />

w<br />

y<br />

where for unstiffened beams:<br />

kv = 5.34<br />

Cv =<br />

190 kv<br />

439<br />

=<br />

h/t F ( h/t ) F<br />

AISC Table C-C2.1 (LRFD and ASD)− Effective Length Factors (K) for Columns<br />

AISC Figure C-C2.2 (LRFD and ASD)− Alignment Chart for Effective Length <strong>of</strong> Columns in Frames<br />

Column capacities<br />

LRFD<br />

Column slenderness parameter:<br />

λc =<br />

⎛<br />

⎜<br />

⎝<br />

r<br />

⎞<br />

⎟<br />

⎠<br />

⎛<br />

⎜ 1<br />

⎜ π<br />

⎝<br />

KL y<br />

max<br />

F ⎞<br />

⎟<br />

E ⎟<br />

⎠<br />

Nominal capacity <strong>of</strong> axially loaded columns (doubly<br />

symmetric section, no local buckling):<br />

φ = 0.85<br />

2<br />

λ<br />

λc ≤ 1.5: φFcr = φ<br />

⎛ c ⎞<br />

⎜0<br />

. 658 ⎟⎠ Fy<br />

⎝<br />

λc > 1.5: φFcr = φ<br />

⎡0.<br />

877⎤<br />

⎢ ⎥ 2<br />

⎢⎣<br />

λc<br />

⎥⎦<br />

See Table 3-50: Design Stress for Compression<br />

Fy<br />

Members (Fy = 50 ksi, φ = 0.85)<br />

w<br />

y<br />

w<br />

ASD<br />

Column slenderness parameter:<br />

Cc =<br />

2<br />

2π<br />

Fy<br />

E<br />

CIVIL ENGINEERING (continued)<br />

Allowable stress for axially loaded columns (doubly<br />

symmetric section, no local buckling):<br />

When<br />

When<br />

⎛ KL ⎞<br />

⎜ ⎟<br />

⎝ r ⎠<br />

Fa =<br />

⎛ KL ⎞<br />

⎜ ⎟<br />

⎝ r ⎠<br />

max<br />

≤ Cc<br />

⎡ 2<br />

( KL/r)<br />

⎤<br />

⎢1<br />

−<br />

2 ⎥ Fy<br />

⎢⎣<br />

2Cc<br />

⎥⎦<br />

5 3(<br />

KL/r)<br />

( KL / r)<br />

+ −<br />

3 8C<br />

8C<br />

max<br />

c<br />

> Cc: Fa =<br />

y<br />

3<br />

c<br />

3<br />

2<br />

12π<br />

E<br />

2<br />

23(<br />

KL / r )<br />

See Table C-50: Allowable Stress for Compression<br />

Members (Fy = 50 ksi)