5.3.5 Specifications<br />

Disks:<br />

Tracks:<br />

Words:<br />

Word format:<br />

Density:<br />

Recording Method:<br />

Words per Disk:<br />

Total Words:<br />

Word Transfer Rate:<br />

Data Storage Capacity<br />

One RF11 can control eight RS11 disks<br />

Each RS11 has 128 data tracks.<br />

Each data track includes 2048 data words.<br />

Data words are recorded in 22 bits<br />

Maximum recording density is 1900 BPI<br />

NRZI<br />

262,144<br />

2,097,152<br />

Data Transfer Rate<br />

60-Hz Power<br />

16.0psec<br />

Minimum Access Time: 258psec<br />

(read amp settling for track switching)<br />

50-Hz Power<br />

19.2J1sec<br />

258J1sec<br />

Average Access Time: 16.9ms 20.3ms<br />

(approximately 1/2-revolution)<br />

Maximum Access Time:<br />

Pri ori ty Level:<br />

Interrupt Vector Address:<br />

Interrupt Caused by:<br />

33.6ms 40.3ms<br />

Priority Interrupt<br />

BR5 (selectable by plug in circuit chip)<br />

204<br />

Function Complete<br />

Error (DCS 15 Set)<br />

Maximum Latency:<br />

12ps: DRL (DAE7) is set and no further transfers<br />

occur for one disk revolution.<br />

Maximum Delay:<br />

3 disk revolutions: MXF (DCS9) is set and operation<br />

halts.<br />

Environmental Requirements<br />

Temperature (Operating): 65° to 90° F<br />

Relative Humidity (Operating):20% to 55% relative<br />

Condensation (Operating or none<br />

Storage):<br />

Vibration/Shock (Operating): Good isolation is provided. To prevent data errors,<br />

extreme vibrations should be avoided while the<br />

RSII is transferring information.<br />

Power Dissipation:<br />

Dependent on the number of disks in the system. Varies from 0.75 kW (2550<br />

BTU/hr) for a I-disk system to 2.42 kW (8230 BTU/hr) for an 8-disk system.<br />

Power Requirements<br />

RSII Motor Power<br />

Voltage: 117 /235± 10%VAC 117 VAC<br />