02.07.2013 Views

PDP11 PeripheralsHbk 1972 - Trailing-Edge

PDP11 PeripheralsHbk 1972 - Trailing-Edge

PDP11 PeripheralsHbk 1972 - Trailing-Edge

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

used by the ACU. It allows the program·<br />

mer to test the ACU to see if the last call<br />

was successfully terminated before he<br />

tries to use it for the next one (Read only).<br />

11·8 Digit Bits (NBl·4) These four bits are control leads to the<br />

ACU. These low order bits of the second<br />

byte make up the BCD digit to be dialed.<br />

Since th,e high·order four are read only. it<br />

does not matter what is in them during a<br />

load, and the programmer may use them<br />

as he wishes. In MA1NT mode, these bits<br />

are used t9 drive the four control lines that<br />

can cause interrupts. See bit 03 for de·<br />

scription (Read /Write).<br />

7 DON E This bit is set to indicate that the ACU is<br />

done with the previously requested action<br />

and ready to accept new data, usually the<br />

next digit in a sequence to be dialed.<br />

The conditions that set DONE are listed<br />

(CRQ must be a one):<br />

1. Transition of PND to one (after CRQ set<br />

or previous DPR set).<br />

2. Transition of DSS to one (after last DPR<br />

or EON).<br />

3. Transition of ACR to one (if timeout er·<br />

ror .. anytime).<br />

4. Transition of DLO to one (if power<br />

switched off) (Read/Write)<br />

6 Interrupt Enable (INTENB) This bit allows the setting of done to cause<br />

an interrupt if ·the master enable bit (bit<br />

02 line # 1 of a system unit) is set<br />

(Read /Write).<br />

5 Data Set Status (FDSS) Control lead from ACU. This is a state·<br />

ment by the ACU that the called party has<br />

answered and that the associated data set<br />

now has control of the line. It is accompa·<br />

nied by the setting of DONE to obtain an<br />

interrupt. It remains set until after the end<br />

of the call (Or until the data terminal<br />

ready lead to the associated modem is<br />

dropped which then drops FDSS).<br />

If the associated modem answers a call<br />

while the dialer is in use (CRQ = 1), then<br />

DSS will be enabled and DONE set. If interrupt<br />

Enable is set there will be an interrupt<br />

(Read only).<br />

4 Present Next Digit (FPND) Control lead from the ACU. This is a<br />

request by the ACU for the program to<br />

load another digit during dialing. It is ac·<br />

companied by the setting of DONE to ob·<br />

119

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!