A B C D E F<br />

4 UNIBUS CONN<br />

3 POWER<br />

2 RESERVED<br />

UNIBUS CONN<br />

Figure 2-30 SS 11 Module Layout<br />

2.4.2 DDII-A Peripheral Mounting Panel<br />

Peripherals may be divided into large and small categories based on the size of<br />

the associated interface logic. If the interface logic (including the M105 Address<br />

Selector and the M782 Interrupt Control) can fit into four module slots, then the<br />

associated device is referred to as a small peripheral. The DDll·A peripheral<br />

mounting panel is a pre·wired system unit designed for mounting up to four small<br />

peripheral interfaces. The physical construction of the DDll·A is similar to the<br />

BSll blank mounting panel.<br />

Use of the DDll·A requires specialized logic cards for the actual interface, since<br />

the pin assignments are fixed for the various control and data signals. Examples<br />

of such interfaces are the DRll·A General Interface (M786 module), LPll Printer<br />

Control (M793 module), CRll Card Reader (M829 module), M792 Diode Memory,<br />

and the KLll Teletype Control (M780 module). Customers may design interfaces<br />

to go into a DDll·A by using the W943 module which allows wire·wrapping of the<br />

integrated circuit interconnections.<br />

Figure 2·31 illustrates module allocation within a DDll·A unit. Slot A2 must be<br />

empty because of power cable overhang; slots S2 and S3 are unused. The DDll·A<br />

is wired to permit the installation of four M7820 modules in column F, four M105<br />

modules in column E, and four double·height device interface modules in col·<br />

umns C and D. The unidirectional grant lines are wired to column D, and each device<br />

interface module must include jumper arrangements to allow selection of the<br />

device priority level at the time of installation. Only SR levels are wired to<br />

this column; devices mounted in a DDll·A unit cannot be assigned to the NPR<br />

priority level without rewiring the panel. An additional constraint imposed on the<br />

interface is that each device may be on only one request level, since both inter·<br />

rupts available through one M7820 module are wired in series and must be at the<br />

same priority level.<br />

If the device requires interface logic that occupies more than one full row of space<br />

in the DDll·A, columns C and D of the second row can be used by using wiring<br />

provided between rows 1 and 2 and rows 3 and 4. If this is done, it is no longer<br />

necessary to add another MI05 and M782 module to slots E and F of the second<br />

row.<br />

Additional considerations that must be noted when using a DDl1-A as well as<br />

specific pin number information is covered in subsequent paragraphs.<br />