Receiver Buffer Register (RBUF)<br />

Transmitter Buffer Register (TBUF)<br />

8.2.4 Specifications<br />

Operating mode:<br />

Data Rates:<br />

Data Format:<br />

Order of Bit:<br />

Transmission:<br />

Parity:<br />

Distortion Input:<br />

Output:<br />

Data Signals:<br />

Control Signals:<br />

Program Interrupts:<br />

Bus Load:<br />

Physical Connection:<br />

Space Required:<br />

Power Required:<br />

Temperature/Humidity:<br />

8-BIT DATA<br />

8-£;3IT DATA<br />

! I<br />

Full- or half-duplex selected under software control.<br />

50, 75, 110, 134.5, 150, 300, 600, 1200, 1800<br />

Baud or one user specified Baud rate between 600<br />

and 10,000. Four speeds are available to the user<br />

under program control. Transmitting and receiving<br />

rates are independent. See DCll models for specific<br />

combinations available.<br />

One start bit. Character size is variable uhder program<br />

control to 5, 6, 7, or 8 data bits. Stop code is<br />

programmable to one or two bits.<br />

Low order bit first.<br />

Computed on incoming data.<br />

Can tolerate up to 40% per character.<br />

Less than 3% per character.<br />

Conforms to EIA RS-232-C and CCITT specifications.<br />

All control leads from the Bell 103, 202 or equivalent<br />

modems are brought into the unit with the exception<br />

of data set ready. All leads are EIA RS-232-<br />

C and CCITT compatible.<br />

Receive done, transmit done, receive overrun, ring,<br />

and carrier transition. (If appropriate enable bits<br />

are set)<br />

One line unit represents a one unit load to the<br />

PDP-l1 UNIBUS. The UNIBUS can handle 18 unit<br />

loads. For more than 18 unit loads a bus extender,<br />

DBll-A, must be used.<br />

25-foot cable with EIA RS-232-C-Compatible 25-Pin<br />

male connector.<br />

1 systems unit for either one or two line interfaces.<br />

2.2 amps of + 5 Volts for the first interface in a<br />

systems unit.<br />

2.0 amps of + 5 Volts for the second interface in a<br />

systems unit.<br />

10° _50 0<br />

C with 20 to 90% noncondensing humidity.<br />

114