T stands for transpose.<br />

Using eqn. (9.14) and (9.15), we get<br />

Symmetrical Components 229<br />

V a1 = 1<br />

3 (V a + bV b + b 2 V c) ...(9.18)<br />

V a2 = 1<br />

3 (V a + b 2 V b + bV c) ...(9.19)<br />

Va0 = 1<br />

3 (Va + Vb + Vc) ...(9.20)<br />

The symmetrical components transformation given above for voltages can also be applied<br />

automatically for a set of currents. Thus<br />

Ia = Ia1 + Ia2 + Ia0 ...(9.21)<br />

Ib = b 2 Ia1 + bIa2 + Ia0 ...(9.22)<br />

Ic = bIa1 + b 2 Ia2 + Ia0 ...(9.23)<br />

Also I a1 = 1<br />

3 (I a + bI b + b 2 I c) ...(9.24)<br />

9.3 POWER INVARIANCE<br />

I a2 = 1<br />

3 (I a + b2 I b + bI c ) ...(9.25)<br />

I a0 = 1<br />

3 (I a + I b + I c) ...(9.26)<br />

The complex power in a three-phase system is given by<br />

S =<br />

T *<br />

VpIp= Va Vb Vc<br />

\ S = VaIa V V V I<br />

*<br />

b b *<br />

c c *<br />

+ + ...(9.27)<br />

Also S = V I = AV AI<br />

p T p *<br />

T T<br />

\ S = VsA A Is<br />

* *<br />

s<br />

T<br />

L<br />

NM<br />

*<br />

s<br />

Ia<br />

I<br />

I<br />

*<br />

b *<br />

c *<br />

O<br />

QP<br />

...(9.28)