Objective Questions 455<br />

108. In terms of ABCD constants, the characteristic impedance of overhead transmission is<br />

I<br />

HG KJ 1<br />

2<br />

(a) A<br />

D<br />

I<br />

HG KJ 1<br />

2<br />

(b) B<br />

C<br />

I<br />

HG KJ 1<br />

2<br />

(c) AB<br />

CD<br />

I<br />

HG KJ 1<br />

2<br />

(d) C<br />

D<br />

109. The units of B and C are respectively<br />

(a) mho, mho (b) ohm, ohm (c) mho, ohm (d) ohm, mho.<br />

110. To increase transmitted power over line,<br />

(a) increase its capacitance (b) increase its line voltage<br />

(c) decrease its line inductance (d) any of these.<br />

111. A long transmission line has value of its A constant as<br />

(a) zero (b) nearly zero<br />

(c) unity (d) nearly equal to unity.<br />

112. When two lines having constants A 1, B 1, C 1, D 1 and A 2, B 2, C 2, D 2 are cascaded in series,<br />

the resultant value of A constant will be<br />

(a) A 1A 2 + B 1C 2 (b) A 1 + A 2 (c) A 1A 2 (d) A 1D 2 + A 2D 1.<br />

113. The cause of transient stability is<br />

(a) alternator loosing its excitation (b) switching ON and O in the line<br />

(c) short circuit fault in the lines (d) all of the above.<br />

114. Corona always causes<br />

(a) insulation failure (b) system faults<br />

(c) radio interference (d) all of these.<br />

115. Corona loss is more in<br />

(a) unstranded conductor (b) ACSR<br />

(c) stranded conductor (d) transposed conductor.<br />

116. Load that depends on the supply frequency is of<br />

(a) fan type (b) heating and welding type<br />

(c) synchronous condenser (d) centrifugal pumps.<br />

117. The inertia constants of two machines are respectively 30 and 42 MJ per MVA. When the<br />

change in frequency due to change in load in first machine is 12 Hz, the change in the<br />

second machine frequency will be<br />

(a) 10 Hz (b) 12 Hz (c) 15 Hz (d) 42 Hz.<br />

118. or cost and safety, the outdoor substations are installed for voltages above<br />

(a)6.6 KV (b) 11 KV (c) 33 KV (d) 132 KV.<br />

119. Lamp flicker in secondary distribution system is controlled by<br />

(a) transformer banking (b) series capacitor<br />

(c) (a) and (b) both (d) induction regulator.<br />

120. Transient stability can be improved by the use of<br />

(a) high inertia machines (b) high speed governors<br />

(c) fast acting voltage regulating system (d) all of the above.<br />

121. When a line to line fault occurs, the SC current of an alternator depends upon its<br />

(a) subtransient reactance (b) transient reactance<br />

(c) short circuit resistance (d) synchronous reactance.<br />

122. Maximum SC current occurs due to<br />

(a) dead short circuit (b) L – L fault<br />

(c) L – G fault (d) L – L – G fault.