02.07.2013 Views

Electrical Power Systems

Electrical Power Systems

Electrical Power Systems

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

452 <strong>Electrical</strong> <strong>Power</strong> <strong>Systems</strong><br />

(c) less than the power factor of sending end<br />

(d) greater than the power factor of sending end.<br />

68. Booster transformers are used to increase the voltage at .... of a transmission line<br />

(a) sending end (b) receiving end (c) intermediate points (d) the centre.<br />

69. The voltage regulation R e of a transmission line of voltage V is<br />

(a) R ea V 2<br />

(b) R ea V (c) R ea 1<br />

2<br />

V<br />

(d) R ea 1<br />

V .<br />

70. Long transmission line has a surge impedance of approximately<br />

(a) 31.4 ohm (b) 75 ohm (c) 282 ohm (d) 400 ohm.<br />

71. The characteristic impedance of a transmission line is given by<br />

I<br />

HG KJ 1<br />

2<br />

I<br />

HG KJ 1<br />

2<br />

(c) bLCg 1<br />

2 (d) LC<br />

(a) L<br />

C<br />

(b) 2p L<br />

C<br />

72. The transfer of real power between interconnected stations is affected by<br />

(a) reactance (b) capacitance (c) inductance (d) all of these.<br />

73. Shunt conductance in power transmission lines is due to leakage over the<br />

(a) conductors (b) insulators (c) poles (d) jumpers.<br />

74. Voltage gradient in a conductor is highest at its<br />

(a) centre (b) surface<br />

(c) circle with half the radius (d) axial line along its average radial circle.<br />

75. Voltage gradient in a cable is highest at the<br />

(a) centre of the conductor (b) surface of the conductor<br />

(c) surface of the sheath (d) all of these.<br />

76. The real part of propagation constant of a transmission line is<br />

(a) phase constant (b) attenuation constant<br />

(c) stability constant (d) reliability factor.<br />

77. or a span length of 2l, horizontal tension at supports as T weight of the conductor per unit<br />

lenght is w, the maximum value of sag will be<br />

(a) 2wl<br />

T<br />

(b) 2<br />

2<br />

wl<br />

T<br />

(c) wl<br />

2T<br />

(d) wl<br />

2<br />

.<br />

2T<br />

78. The sag of the transmission line is affected by<br />

(a) its own weight and weight of the ice<br />

(b) temperature and wind condition<br />

(c) both (a) and (b)<br />

(d) either of (a) or (b).<br />

79. Most commonly used supports for high tension lines is<br />

(a) wooden poles (b) steel poles (c) cross bars (d) latticed steel poles.<br />

80. When horizontal tension H increases by 20%, the tension T changes by a<br />

(a) decrease of 20% (b) decrease of 10%<br />

81. A transmission line is a circuit with<br />

(a) distributed parameters of R, L, C and G<br />

(b) lumps of R and L<br />

(c) lumps of L and C<br />

(d) both (b) and (c).<br />

(c) no change (d) increase of 20%.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!