4. Input / Output Signal <strong>Functions</strong><br />

4.5 Amplifier Status Change Diagram<br />

Main power ON<br />

Reset incomplete<br />

Reset operation<br />

Servo OFF Status<br />

Reset complete<br />

Idle (Stop status)<br />

Servo ON Status<br />

In-Position operation<br />

Zero-return operation<br />

Cancel<br />

Power Limit 3<br />

Velocity 0<br />

Fixed excitation<br />

STOP<br />

ALM<br />

CLR<br />

Power<br />

Limit 3<br />

Recoverable alarm<br />

Fixed<br />

excitation<br />

Unrecoverable alarm<br />

Power<br />

Limit 3<br />

Fixed<br />

excitation<br />

Alarm status<br />

(1) The reset operation is automatically initiated when the amplifier detects that the power of the<br />

main circuit is within the specified voltage range. After initialization is complete, the status<br />

automatically changes to “Servo ON". If the reset operation is completed once, the<br />

initialization will not be performed. Use the STOP signal to maintain "Servo OFF” status.<br />

(2) If a STOP or alarm occurs, the motor decelerates with fixed excitation until it is stopped. After<br />

the motor stops, the excitation current selected for Power Limit 3 is applied.<br />