<strong>5.</strong> <strong>Comm<strong>and</strong>s</strong> <strong>and</strong> <strong>Functions</strong><br />
<strong>5.</strong> 5 Point <strong>and</strong> Program <strong>Comm<strong>and</strong>s</strong><br />
<strong>5.</strong> <strong>5.</strong> 1 Point <strong>and</strong> program control comm<strong>and</strong>s<br />
Comm<strong>and</strong> Code: 80 (50h)<br />
Data Length:0 bytes<br />
START Comm<strong>and</strong><br />
This comm<strong>and</strong> remotely starts the point or program previously specified with 55h.<br />
Before using the START comm<strong>and</strong>, always set the execution target using 55h.<br />
Comm<strong>and</strong> Code: 81 (51h)<br />
STEP Operation<br />
Data Length: 3 bytes<br />
DAT No Function Setting range Setting unit<br />
DAT1 Program number When 1 PRG selected: 0<br />
When 128 PRG selected: 0 to 7Fh<br />
When 32PRG selected: 0 to 1Fh<br />
DAT2,3 Line number When 1 PRG selected: 0 to 3FFh<br />
When 128 PRG selected: 0 to 8<br />
When 32PRG selected: 0 to 1Fh<br />
This comm<strong>and</strong> specifies the STEP operation (line by line execution) of the program.<br />
Note that the range for program number <strong>and</strong> line number depends on the settings performed by<br />
comm<strong>and</strong> 1Bh.<br />
Response:<br />
As a response to the STEP operation comm<strong>and</strong>, the next executable line (2 bytes) is returned. The<br />
response format is the following:<br />
Packet length Address Response status Line number Line number Checksum<br />
(lower)<br />
(higher)<br />
* If the STEP operation is executed in the middle of a Gosub/Return comm<strong>and</strong>, <strong>and</strong> the next<br />
executable line is unknown, the response will be FFFF.<br />
When a Timer Wait is executed in STEP mode, the setting time of the Timer will be disabled.<br />
<br />
<br />
Comm<strong>and</strong> Code: 82 (52h)<br />
Data Length:0 bytes<br />
Program Stop<br />
This comm<strong>and</strong> aborts the program operation. The amplifier maintains the servo ON status.<br />
* Program lines that have already started execution will not be aborted. To abort the movement itself,<br />
use the STOP comm<strong>and</strong>.<br />
* The Program stop comm<strong>and</strong> can only be used during program execution; otherwise, a comm<strong>and</strong><br />
error will be generated.<br />
* Refer to comm<strong>and</strong> code 8Ah to read the stopped program line.<br />
5-33