<strong>5.</strong> <strong>Comm<strong>and</strong>s</strong> <strong>and</strong> <strong>Functions</strong><br />

Note 1) If the zero-sensor (SDN) type zero-return start function is used, pin 9 will be the zero-sensor<br />

input. Follow the instructions below to allocate the zero-sensor signal function.<br />

Set comm<strong>and</strong> 14h, DAT4, Bit7 (SDN) = 0 to use pin 9 as the zero-sensor input.<br />

a) If the H. Limit <strong>and</strong> zero-sensor are shared: set the H. Limit function of the desired direction.<br />

b) If only the zero-sensor function is used: set the generic input port function.<br />

c) If you want to use the zero-sensor (SDN) type zero-return function: set the desired function.<br />

Note 2) If the point input was selected, see the table below for the point bit number of each input pin.<br />

Input port Pin 6 Pin 7 Pin 8 Pin 9 Pin 12<br />

Point Bit No Point3 Point4 Point5 Point6 Point7<br />

* Input ports with settings other than point functions will be interpreted as point or program bit = 0.<br />

Example: Pin 6 = Generic input, Pin 7 = Point4 (Point1, 2=0 (OFF))<br />

Point1<br />

(Pin 4)<br />

Point2<br />

(Pin 5)<br />

(Pin 6) (Pin 7) Point No<br />

0 0 0 (Fixed) 0 0<br />

0 0 0 (Fixed) 1 8<br />

Note 3) If the zero-return start function is allocated, it is necessary to set the zero-return start<br />

conditions first, using comm<strong>and</strong> 53h.<br />

Note 4) The following table shows the monitored pins when an input pin monitor function is set<br />

to an output port function.<br />

Output port Pin 16 Pin 17 Pin 18 Pin 19 Pin 20<br />

Monitor pin Pin 6 Pin 7 Pin 8 Pin 9 Pin 12<br />

The monitor output monitors the hardware status of the input port, regardless of the input port functions<br />

<strong>and</strong> amplifier status. When the input port coupler is ON, output Tr = ON.<br />

Note 5) Setting method of a Zone output signal<br />

When set the output function which supported with 1 to 1 for ZONE No set in comm<strong>and</strong> 2Ah or<br />

31h, please choose output Type0 <strong>and</strong> 8-22.<br />

When a binary outputs Zone No, please choose output Type23 to 26.<br />

5-13