<strong>5.</strong> <strong>Comm<strong>and</strong>s</strong> <strong>and</strong> <strong>Functions</strong><br />

Comm<strong>and</strong> Code: 134 (86h)<br />

Data Length: 0 bytes<br />

ALM monitor<br />

This comm<strong>and</strong> reads the alarm history.<br />

Returned data The returned data is 8 bytes.<br />

DAT1: Current alarm status<br />

DAT 2 to 8: Alarm history (in the order of most recent to oldest)<br />

* A low voltage ALM is saved only if the power is recovered after detecting the low<br />

voltage.<br />

Abbreviation Code (Hex) ALM description<br />

No alarm 00 Normal status<br />

DE 01 Sensor disconnected<br />

OV 02 Input power voltage is above the specification range<br />

MPE 03 Input power voltage is below the specification range<br />

RSTE 04 Initialization error (overload)<br />

Power line disconnected<br />

OVF 05 Position deviation abnormal<br />

OL 06 Overload stop<br />

OS 07 Overspeed<br />

RGOL 08 Regeneration voltage is over the specified value<br />

ORG 09 Zero-return error<br />

CNT OVF 0A Position Deviation Counter over flow<br />

Wrap around 0B Absolute position counter sign reversal<br />

Push 0C Push ErrorWide swing<br />

MO OH 0E Motor overheat detection<br />

AMP OH 0F Amplifier overheat detection<br />

EEPER 10 Non-volatile memory error<br />

PAM 11 PAM voltage abnormal<br />

OC1 12 Overcurrent detectionHardware<br />

LA 13 Sensor phase error<br />

OC2 14 Overcurrent detectionSoft Ware<br />