<strong>5.</strong> <strong>Comm<strong>and</strong>s</strong> <strong>and</strong> <strong>Functions</strong><br />
Comm<strong>and</strong> Code: 75 (4Bh)<br />
Data Length: 1 byte<br />
Bit Out<br />
DAT No Function Setting range Setting unit<br />
DAT1 Bit Out 0 to 1Fh <br />
Sets the output status of the generic output port.<br />
Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0<br />
* * * Out5 Out4 Out3 Out2 Out1<br />
0: Photocoupler OFF 1: Photocoupler ON<br />
* This comm<strong>and</strong> is valid only at generic output ports set for output port functions using comm<strong>and</strong><br />
16h. For non-generic outputs, this function will be ignored.<br />
Comm<strong>and</strong> Code: 76 (4Ch)<br />
Data Length:0 bytes<br />
STOP Comm<strong>and</strong><br />
This comm<strong>and</strong> initiates an emergency stop. If the motor is in motion, it stops with the maximum<br />
possible deceleration rate, <strong>and</strong> the amplifier status changes to servo OFF.<br />
* The comm<strong>and</strong> operates using an OR condition with the STOP input port.<br />
* If used during program execution, the program execution will stop.<br />
Comm<strong>and</strong> Code: 77 (4Dh)<br />
Data Length:0 bytes<br />
STOP Clear<br />
Cancels the STOP initiated by a STOP comm<strong>and</strong>. At the time of the STOP clear, the amplifier status<br />
automatically changes to servo ON.<br />
* This comm<strong>and</strong> does not clear the STOP signal at an input port.<br />
Comm<strong>and</strong> Code: 78 (4Eh)<br />
Data Length:0 bytes<br />
Interlock<br />
This comm<strong>and</strong> aborts movement. A deceleration stop is performed using the deceleration rate set at<br />
the time of receiving the comm<strong>and</strong>. The stop position becomes the target position. The system keeps<br />
the SON status, <strong>and</strong> performs a deceleration stop. Move comm<strong>and</strong>s during interlock will generate a<br />
comm<strong>and</strong> error.<br />
* During interlock, initialization is not executed.<br />
Comm<strong>and</strong> Code: 79 (4Fh)<br />
Data Length:0 bytes<br />
Interlock Clear<br />
Clears the Interlock initiated by an Interlock comm<strong>and</strong>.<br />
* This comm<strong>and</strong> does not clear the interlock of an input port.<br />