5. Commands and Functions - Sanyo Denki America, Inc.
5. Commands and Functions - Sanyo Denki America, Inc.
5. Commands and Functions - Sanyo Denki America, Inc.
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>5.</strong> <strong>Comm<strong>and</strong>s</strong> <strong>and</strong> <strong>Functions</strong><br />
<strong>5.</strong> 6 RD comm<strong>and</strong>s<br />
Comm<strong>and</strong> Code: 128 (80h)<br />
Data Length: 1 byte<br />
Parameter Read<br />
DAT No Function Setting range Setting unit<br />
DAT1 RD target comm<strong>and</strong> code SysytemDirect Comm<strong>and</strong> <br />
This comm<strong>and</strong> reads the setting data of a direct comm<strong>and</strong> or a system comm<strong>and</strong>.<br />
* The returned data represents the setting data stored in RAM.<br />
Returned data Comm<strong>and</strong> code + data content<br />
Comm<strong>and</strong> Code: 129 (81h)<br />
Data Length: 1 byte<br />
Point Read<br />
DAT No Function Setting range Setting unit<br />
DAT1 RD target point number 0 to 80h80hZero-Return Profile <br />
This comm<strong>and</strong> reads the data content of the specified point number.<br />
Returned data Comm<strong>and</strong> code + data content<br />
Comm<strong>and</strong> Code: 130 (82h)<br />
Data Length: 3 bytes<br />
Program Read<br />
DAT No Function Setting range Setting unit<br />
DAT1 RD target program number Depend on PRG No <br />
DAT2,3 Line number Depend on PRG No <br />
This comm<strong>and</strong> reads a single line of the specified program.<br />
Returned data Comm<strong>and</strong> code + data content<br />
<br />
5-41