<strong>5.</strong> <strong>Comm<strong>and</strong>s</strong> <strong>and</strong> <strong>Functions</strong><br />

Comm<strong>and</strong> Code:01h<br />

Data Length:0 bytes<br />

Initialization<br />

Initializes the amplifier status to power-up status. ROM parameters are loaded to RAM.<br />

Comm<strong>and</strong> Code:02h<br />

Data Length:0 bytes<br />

Parameter Clear<br />

Resets RAM parameters to their factory settings. (To clear point or program data, use 05h.)<br />

* When resetting the ROM parameters, use the parameter Save comm<strong>and</strong> (03h) after the P. CLR<br />

comm<strong>and</strong>.<br />

Comm<strong>and</strong> Code:03h<br />

Data Length:0 bytes<br />

Parameter Save<br />

Saves RAM parameters to the ROM.<br />

* If a reset is performed without saving the parameters, the values will be lost.<br />

Comm<strong>and</strong> Code:04h<br />

Data Length:0 bytes<br />

Parameter load<br />

Loads the ROM parameters to RAM.<br />

* The same operation is performed at power-up <strong>and</strong> when using the initialization comm<strong>and</strong>.<br />

Comm<strong>and</strong> Code:05h<br />

Point or Program Clear<br />

Immediately clears all point <strong>and</strong> program data.<br />

Data Length:0 bytes<br />

Comm<strong>and</strong> Code:06h<br />

ALM History Clear<br />

Clears the alarm history.<br />