Comm<strong>and</strong> Code:01h<br />
Data Length:0 bytes<br />
Initialization<br />
Initializes the amplifier status to power-up status. ROM parameters are loaded to RAM.<br />
Comm<strong>and</strong> Code:02h<br />
Data Length:0 bytes<br />
Parameter Clear<br />
Resets RAM parameters to their factory settings. (To clear point or program data, use 05h.)<br />
* When resetting the ROM parameters, use the parameter Save comm<strong>and</strong> (03h) after the P. CLR<br />
comm<strong>and</strong>.<br />
Comm<strong>and</strong> Code:03h<br />
Data Length:0 bytes<br />
Parameter Save<br />
Saves RAM parameters to the ROM.<br />
* If a reset is performed without saving the parameters, the values will be lost.<br />
Comm<strong>and</strong> Code:04h<br />
Data Length:0 bytes<br />
Parameter load<br />
Loads the ROM parameters to RAM.<br />
* The same operation is performed at power-up <strong>and</strong> when using the initialization comm<strong>and</strong>.<br />
Comm<strong>and</strong> Code:05h<br />
Point or Program Clear<br />
Immediately clears all point <strong>and</strong> program data.<br />
Data Length:0 bytes<br />
Comm<strong>and</strong> Code:06h<br />
ALM History Clear<br />
Clears the alarm history.<br />
Data Length:0 bytes<br />