SUBJECT: Firehawk MMR SCBA Daily/Weekly Check for Reserve SCBA SOP: 300.20<br />

CATEGORY: Emergency Response Operations PAGE: 2 of 2<br />

3. Press the Mode button (the green button on the upper left of ICM) once for Illumination<br />

Mode and twice for time remaining at current breathing rate (will display 3 dashes).<br />

4. Crack the bypass valve (red knob on Firehawk regulator) slowly to bleed off pressure until<br />

the ICM alarm gauge needle drops below 1175 psig (the beginning of the red zone on the<br />

ICM gauge) The ICM alarm and the audi-alarm bell will ring until the pressure is less that<br />

200 psig.<br />

5. When the pressure falls below 200 psig, turn the ICM off by pressing the Reset Button<br />

(yellow button on the right side of the ICM) twice over a 1 second period. An extended<br />

single tone will sound indicating the unit has been turned off<br />

6. Close the bypass valve, store the Firehawk regulator in the STAND-BY belt mount.<br />

7. Complete the daily check sheet that is maintained in the apparatus.<br />

8. When a unit is taken out of service it is to be tagged and placed in the SCBA room at <strong>fire</strong><br />

<strong>station</strong> number three.<br />

As required by the Texas Fire Commission SCBA daily check sheets must be<br />

completed each morning.<br />

Forms will be pages 3 and 4.<br />

rev: 4/94, 3/99