Voice and Resource Board <strong>Installation</strong><br />

GammaLink Fax Board<br />

Table 13-5<br />

GammaLink Fax Base Board Parts Description<br />

Part<br />

SW1 Switch Block<br />

XTERM<br />

P100<br />

UA1~UA3<br />

UB1~UB3<br />

UC1~UC3<br />

UD1~UD3<br />

UE1~UE3<br />

UF1~UF3<br />

Function<br />

Four DIP switches. Specifies which I/O ports the board uses when<br />

communicating with the host processor. The switch also defines I/O ports for the<br />

SC2000 and its FPGA configuration register.<br />

Terminator socket for PEB bus mode operation.<br />

Connector for SCBus.<br />

Fax Cell A<br />

Fax Cell B<br />

Fax Cell C<br />

Fax Cell D<br />

Fax Cell E<br />

Fax Cell F<br />

Voice and Resource<br />

Board <strong>Installation</strong><br />

Install GammaLink Fax CP-6/SC Board<br />

1. I/O Address – Verify the four DIP switches on the SW1<br />

block switch are in the default position of Off (Figure<br />

13-14). This sets the I/O address to “0.”<br />

If a DIP switch is not in the Off position, use a ballpoint<br />

pen or a small screwdriver and gently move the switch to<br />

the Off setting.<br />

Each I/O address represents six physical-channel<br />

hexadecimal addresses. For example, I/O address 0 is<br />

350, 360, 370, 250, 260, and 270.<br />

ON<br />

1 2 3 4<br />

3804<br />

Bracket<br />

Figure 13-14 SW1 Switch Settings<br />

Note<br />

See the GammaLink Fax <strong>Installation</strong> Guide that came with the board for settings for<br />

additional boards.<br />

CAUTION!<br />

If you find a PEB Terminator on the<br />

board’s XTERM Socket (Figure 13-15),<br />

remove it. The board in SCbus mode is<br />

terminated internally and does not<br />

require a terminator. If left on the board,<br />

the terminator causes the board to not<br />

function properly in the Stratagy ES.<br />

Network Module<br />

Configuration<br />

XTERM<br />

Socket<br />

Resource Module<br />

Configuration<br />

4752<br />

Figure 13-15<br />

XTERM Socket<br />

2. Select an empty expansion bus slot. Remove the slot’s retaining screw and access cover plate.<br />

Keep the cover plate for possible future use.<br />

3. Insert the board’s edge connector into the slot. Press firmly until the board is securely seated in<br />

place. Replace and tighten the retaining screw.<br />

4. Repeat this for each GammaLink Fax board you are installing.<br />

Stratagy ES I&M 06/02 13-15