The successful application of motion control valves,particularly in areas that are demanding involves theanticipation and resolution of numerous factors only some ofwhich can be discussed in this article. Motion control valvesare adjustable, are available in several pressure ranges withmany pilot ratio options. Most of the valves fit in a commoncavity (the exception being the fully balanced, 1CEB and zerodifferential, 1CPB versions when required with an externalrather than an atmospheric vent) and are available in sizesfrom 30 to 300 L/min. The flexibility of cartridge valvetechnology can therefore be easily applied to bring stability.The standard range of valves described here can be used toFigure 6. 1CPB(D) zero differential overcentre valveCYLINDER (1)VALVE (2)PILOT (3)VENT (4)solve the vast majority of motion control problems and we areconstantly developing new valves that will further improvestability and load control.Graph 2. Unstable system225200175Pressure bar150125100CYLINDER PRESSURE75502510 20 30 40 50 60Time secGraph 3. Stable system using counterbalance valve225200175CYLINDER PRESSURE150Pressure bar12510075502510 20 30 40 50 60Time sec