12.07.2015 Views

2 - TCA spa

2 - TCA spa

2 - TCA spa

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

PERFORMANCES220 (Standard valve)WORKING PRESSURE (BAR)0250200150100500FLOW (US GPM)0.2 0.5 0.7 1.0 1.2 1.5 1.7 2.0 2.2 2.5NORMALLYOPEN1 2 3 4 5 6 7FLOW (LITRES/MIN)NORMALLY CLOSEDSELECTOR8 90103750300022501500750WORKING PRESSURE (PSI)PERFORMANCES220H (Heavy duty valve)WORKING PRESSURE (BAR)FLOW (US GPM)0 0.2 0.5 0.7 1.0 1.2 1.5 1.7 2.0 2.2 2.52503750SELECTOR2003000NORMALLY150CLOSED2250NORMALLY OPEN10015005075000 1 2 3 4 5 6 7 8 9 10FLOW (LITRES/MIN)WORKING PRESSURE (PSI)CARTRIDGE ONLYBASIC CODE: S220 / S220H48.0023.5036.00COMPLETE VALVEBASIC CODE: S220 / S220HBody ONLY part numbersBSP, aluminium1/4” B77243/8” B6684SAE, aluminium3/8” B651657.201/4” 3/8” PORTS55.5038.5011.1014.7024.00 A/F44.003/4"-16-UNF-2A9.553228.3021338.1063.5011ø14.20ø15.8014.8028.6047.602 HOLESø7.1 THRO'12.7025.40Where measurements are critical request certified drawingsORDERING CODE EXAMPLES220* N H 24 3WBasic CodeS220 = (standard valve)S220H = (heavy duty valve)SealsN = NitrileV = VitonManual Override (consult factory for availability)1 = Push and twist2 = ScrewWe reserve the right to change specifications without noticePort Sizes2W = 1/4” BSP3W = 3/8” BSP 6T = 3/8” SAEVoltage12 = 12 VDC 110 = 110 VAC24 = 24 VDC 220 = 220 VACCoil TerminationH = DIN43650F = Flying LeadsDM = Deutsch MouldedOther terminations available on request11-2112.B

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!