12.07.2015 Views

2 - TCA spa

2 - TCA spa

2 - TCA spa

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

1CEESH SERIES DUAL OVERCENTRE VALVEWITH BRAKE SHUTTLE - PILOT ASSISTED1CEESH35C1C2V1BV26APPLICATIONOvercentre Valves give static and dynamic control ofloads by regulating the flow into and out of hydraulicactuators. When installed close to or within anactuator, the overcentre valve will stop runaway in theevent of hose burst and if open centre directionalcontrol valves are used, will allow thermal expansionrelief of the hydraulic fluid.These dual overcentre valves also contain a brakerelease shuttle valve which ensures that pressure isapplied to a brake release circuit regardless ofwhether pressure is applied to ports V1 or V2. Thesemultifunction valves are normally used for the staticand dynamic control of systems using motors or semirotaryactuators.OPERATIONThe check section allows free flow into the actuatorthen holds and locks the load against movement. Thepilot assisted relief valve section will give controlledmovement when pilot pressure is applied. The reliefsection is normally set to open at a pressure at least1.3 times the maximum load induced pressure but thepressure required to open the valve and allowmovement depends on the pilot ratio of the valve. Foroptimisation of load control and energy usage, achoice of pilot ratios is available.The pressure required to open the valve and startactuator movement can be calculated as follows:Pilot Pressure = (Relief Setting) - (Load Pressure)Pilot RatioPILOT RATIOS2.5:1 Best suited for extremely unstableapplications such as long booms orflexible frameworks.5:1 Best suited for applications where load(Standard) varies and machine structure can induceinstability.10:1 Best suited for applications where loadremains relatively constant.FEATURESThese valves have the excellent load control and safetyfeatures of the dual overcentre valve with the addition of aport for a brake release line. Smooth, safe performance.SPECIFICATIONSFigures based on: Oil Temp = 40°C Viscosity = 40 cStRated FlowMax SettingCartridge MaterialBody MaterialMounting PositionWeightSeal Kit NumberRecommendedFiltration LevelOperating TempLeakageNominal ViscosityRange30 litres/min (8 US GPM)Max Load InducedPressure: 270 bar (4000 psi)Relief Setting:5 to 500 cSt350 bar (5000 psi)Working parts hardened and groundsteel. External surfaces electrolessnickel platedSteelLine mounted2.20 kg (4.84 lbs)SK816 (Nitrile)BS5540/4 Class 18/13(25 micron nominal)-20°C to +90°CSK816V (Viton)0.3 millilitres/min nominal (5 dpm)Integrated Hydraulics LtdIntegrated Hydraulics IncCollins Road, Heathcote Ind. Est., Warwick, CV34 6TF, UK.7047 Spinach Drive, Mentor, Ohio 44060, USATel: +44 (0) 1926 881171 Fax: +44 (0) 1926 315729 Tel: (440) 974 3171 Fax: (440) 974 3170Website: www.integratedhydraulics.comWebsite: www.integratedhydraulics.com6-271.D

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!