12.07.2015 Views

2 - TCA spa

2 - TCA spa

2 - TCA spa

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

PERFORMANCEFLOW (US GPM)2501.3 2.6 3.9 5.2 6.5 7.89.13625WORKING PRESSURE (BAR)200150100503-2 AND 4-1OR3-4 AND 2-1290021751450725WORKING PRESSURE (PSI)00 5 10 15 20 25 30 35FLOW (LITRES/MIN)NOTE:For applications were unbalanced pressure and return flows are encountered the flow rate of this valve should be reduced, pleasecontact our sales office for details.0CARTRIDGE ONLYCOMPLETE VALVE3/8” 1/2” PORTSBASIC CODE: S54249.0021.0035.50BASIC CODE: S542Body ONLY part numbersBSP, aluminium SAE, aluminium3/8” B192401/2” B19228 1/2” B1922963.5066.0050.0062.5025.40 A/F7/8"-14-UNF-2Aø15.80ø17.40ø19.008.30143234.502 HOLESø7.1 THRO'6.35432131.8050.8073.2050.5018.5016.0031.8082.6011Where measurements are critical request certified drawingsORDERING CODE EXAMPLES542 N H24 3WBasic CodeS542SealsN = NitrileV = VitonManual Override (consult factory for availability)2 = ScrewWe reserve the right to change specifications without noticePort Sizes3W = 3/8” BSP4W = 1/2” BSP 8T = 1/2” SAEVoltage12 = 12 VDC 110 = 110 VAC24 = 24 VDC 220 = 220 VACCoil TerminationH = DIN43650F = Flying LeadsDM = Deutsch MouldedOther terminations available onrequest11-3212.B

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!