1.61.61.6COMPLETE VALVEBASIC CODE:1CEBL356FLANGE MOUNTEDNote: Cylinder port bolt holes areslotted for fitment to both SAE 3000 &SAE 6000 mounting faces.86.5043.2540.0038.00CRS19.00 26.19CRS13.88 CRS13.10 CRS28.5828.58CRS26.19CRS4 MTGHOLESTHROUGH40.0038.0019.0013.88 CRS13.88 CRSECT3V47.5095.0096.00128.0013.88 CRS13.10 CRSTORQUE:7.1 Nm18.00CBLEED13.88 CRS13.88 CRSVCT4ETORQUE:15.8 NmTORQUE:150 Nm47.5095.00155.0064 MTG HOLESM12 X 1.75X 20 DEEP11.004 MTG HOLESM12 X 1.75X 20 DEEP28.58CRS28.58CRS87.50CT1CT228.58CRS1PSC30-F-35PTORQUE TO 45 NmSET AT 350 BAR1CPBD120-F2PTORQUE TO 100 NmSET AT 10 BAR28.58CRS23.00PILOTDRAIN26.0011.0075.50Tightening torque of “F” adjusterlocknut - 20 to 25 NmWhere measurements are critical request certified drawingsORDERING CODE EXAMPLE1CEBL356 F 1 6 35 PBasic Code1CEBL356 = Cartridges and BodyAdjustment MeansF = Screw AdjustmentPort Size1 = 1” SAE Flange Cylinder Port(Slotted for 3000 and 6000)1” SAE Flange Valve Port (Thread G 3/4)1/8” BSP Bleed Port1/4” BSP All Other PortsSealsP = Contains polyurethane andstandard seal.Pressure Range @ 4.8 l/min35 = 70-350 bar. Std setting 350 barStd Setting made at 4.8 litres/minSAE Port Type6 = SAE 6000 (Valve Port)We reserve the right to change specifications without notice6-422.C