PERFORMANCES221 (Standard valve)PERFORMANCES221H (Heavy duty valve)FLOW (US GPM)FLOW (US GPM)WORKING PRESSURE (BAR)250200150100500.5 1 1.5 2 2.5 3 3.5NORMALLY OPENNORMALLY CLOSEDSELECTOR3625290021751450725WORKING PRESSURE (PSI)WORKING PRESSURE (BAR)250200150100500.5 1 1.5 2 2.5 3 3.5 4 4.5NORMALLY OPENNORMALLY CLOSEDSELECTOR53625290021751450725WORKING PRESSURE (PSI)000 2 4 6 8 10 12 14FLOW (LITRES/MIN)00 2 4 6 8 10 12 14FLOW (LITRES/MIN)16 18020CARTRIDGE ONLYCOMPLETE VALVE1/4” 3/8” PORTSBASIC CODE: S221 / S221H48.0023.5036.00BASIC CODE: S221 / S221HBody ONLY part numbersBSP, aluminium SAE, aluminium1/4” B77243/8” B6684 3/8” B651657.2055.5038.5011.1014.7044.0024.00 A/F3/4"-16-UNF-2A9.553228.3021338.1063.5011ø14.20ø15.8014.8028.6047.602 HOLESø7.1 THRO'12.7025.40Where measurements are critical request certified drawingsORDERING CODE EXAMPLES221* N H 243WBasic CodeS221 = (standard valve)S221H = (heavy duty valve)SealsN = NitrileV = VitonManual Override (consult factory for availability)1 = Push and twist2 = ScrewWe reserve the right to change specifications without noticePort Sizes2W = 1/4” BSP3W = 3/8” BSP 6T = 3/8” SAEVoltage12 = 12 VDC 110 = 110 VAC24 = 24 VDC 220 = 220 VACCoil TerminationH = DIN43650F = Flying LeadsDM = Deutsch MouldedOther terminations available on request11-2312.B