PERFORMANCEPERFORMANCEFLOWING BACK THROUGH THE VALVEFLOWING IN ONE DIRECTION ONLYFLOW (US GPM)FLOW (US GPM)2501.3 2.6 3.9 5.2 6.5 7.89.110.436252501.3 2.6 3.9 5.2 6.5 7.89.1 10.43625WORKING PRESSURE (BAR)200150100503-2-4-1 & 3-4-2-1290021751450725WORKING PRESSURE (PSI)WORKING PRESSURE (BAR)200150100503-23-4290021751450725WORKING PRESSURE (PSI)00 5 10 15 20 25 30 35FLOW (LITRES/MIN)400000 5 10 15 20 25 30 35 40FLOW (LITRES/MIN)NOTE: Higher flows available on requestCARTRIDGE ONLYCOMPLETE VALVE3/8” 1/2” PORTSBASIC CODE: S57249.0021.0035.50BASIC CODE: S572Body ONLY part numbersBSP, aluminium SAE, aluminium3/8” B192401/2” B19228 1/2” B1922963.5050.00125.0062.5027.00 A/F7/8"-14-UNF-2Aø15.80ø17.40ø19.0050.0012.0014322 HOLESø7.1 THRO'34.506.35432131.8050.8073.2050.5018.5016.0031.8082.6011Where measurements are critical request certified drawingsORDERING CODE EXAMPLES572 N H 24 3WBasic CodeS572SealsN = NitrileV = VitonManual Override (consult factory for availability)4 = Push/PullWe reserve the right to change specifications without noticePort Sizes3W = 3/8” BSP4W = 1/2” BSP 8T = 1/2” SAEVoltage12 = 12 VDC 110 = 110 VAC24 = 24 VDC 220 = 220 VACCoil TerminationH = DIN43650F = Flying LeadsDM = Deutsch MouldedOther terminations available on request11-3812.B