PRESSURE DROPCARTRIDGE ONLYBASIC CODE: 4CKD90FLOW-US GPM250 5 1015202518.5MAX32.0 A/F20320M27x1.511.5 51.0MAX7.0MINPILOT (3)VALVE (2)CYL (1)ø11.0C1C286.538.1V1V240.518.0PRESSURE-BAR15105020240PILOTED OPEN160FREE FLOW8040 60 80 100 0FLOW-LITRES/MINPRESSURE-PSINote. Ensure cavity clears nose end of cartridgeSINGLE VALVEBASIC CODE: 4CKD95Body ONLY part numbersBSP, aluminium1/2” B13625SAE, aluminium1/2” B108061/2” PORTS DUAL VALVEBSP, steel1/2” B13626SAE, steel1/2” B10922BASIC CODE: 4CKKD95 (INTERNALLY CROSS PILOTED)Body ONLY part numbersBSP, aluminium1/2” C13627SAE, aluminium1/2” C108071/2” PORTSBSP, steel1/2” C13628SAE, steel1/2” C11561770.036.0258.021388.5 MAX70.036.058.0V1C1C2V288.5 MAX138.119.010.056.076.238.119.0 10.0107.0127.02 HOLES Ø11.0 THRO'2 HOLES Ø11.0 THRO'Where measurements are critical request certified drawingsORDERING CODE EXAMPLE4CK****14W S 3Basic Code4CKD90 = Cartridge Only4CKD95 = Cartridge and Body4CKKD95 = Cartridges and Dual BodyPilot Port Sizes1 = InternalPort Sizes - Bodied Valves Only4W = 1/2” BSP. 1/4” BSP. Pilot Port8T = 1/2” SAE 1/4” SAE Pilot PortOptional Pilot SealOmit if not requiredSealsS= Nitrile (For use with mostindustrial hydraulic oils)SV = Viton (For high temperature andmost special fluid applications)We reserve the right to change specifications without notice7-164.C