12.07.2015 Views

Symantec™ Security Gateways Reference Guide - Sawmill

Symantec™ Security Gateways Reference Guide - Sawmill

Symantec™ Security Gateways Reference Guide - Sawmill

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

156 Log messagesInformational messages (100-199)155 - Configuration discardedDescription: Any configuration edits that have been made since the last activation have been deleted. The userparameter identifies the administrator, and the revision parameter identifies the revision.155 - The Scan Engine has updated its virus definitionsDescription: The Scan Engine has updated its virus definitions to reflect the current list.164 - NDIS descriptor allocation scale factor set and number per direction is 512 times valueDescription: The Microsoft Windows driver has set the scale factor according to the ScaleFactor registry value. Thenumber of buffers statically allocated is two times 512 times the value in the ScaleFactor registry entry. Anadditional number equal to this result is dynamically allocated and freed.For example, if the ScaleFactor value is 6, 3072 receive buffers and 3072 transmit buffers are pre-allocated.In addition, another 3072 receive buffers and 3072 transmit buffers are dynamically allocated asnecessary. These numbers indicate the number of packets concurrently being processed within the driver.164 - Received command to reload filter configurationDescription: A command is received to reload the filter configuration.170 - Attempting to re-synchronize modem for retry countDescription: Notify daemon makes count attempts to synchronize the modem.170 - Dialing phone numberDescription: This is a pager notification, stating the progress of the connection to the modem.170 - Hanging up the modemDescription: This is a pager notification, stating the progress of the pager transmission.170 - Modem is now synchronizedDescription: This is a pager notification, stating the progress of the pager transmission.170 - Waiting for a specific string using a retry count or timeoutDescription: Notify daemon is waiting for a particular modem response.171 - Driver log messages at this level suppressedDescription: Logging of driver log messages is suppressed until the volume of messages decreases.171 - SESA Agent installedDescription: The software that lets the security gateway communicate with the SESA Manager has been installed andconfigured.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!