Log messagesWarning messages (300-399)193301 - <strong>Security</strong> policy uses transport mode VPN policy. Remote entity and security gateway musthave the same IP addressDescription: This indicates a misconfiguration.301 - Send bullfrog command X failed with local error YDescription: An attempt to send a command X to the bullfrog daemon failed, with a local error Y. This error is caused bytimeout while waiting for a response from the bullfrog daemon.301 - Send bullfrog command X failed with remote error YDescription: An attempt to send a command X to the bullfrog daemon failed, with a remote error Y. Ignore the error ifthe command X is 13 (Get Node Status) and remote error Y is a non-zero value.301 - Send of local file failedDescription: Unable to send file because of communication errors.301 - Setrlimit (RLIMIT_NOFILE) failedDescription: Setting user specified RLIMIT_NOFILE has failed. The default value is used.301 - Setsockopt failsDescription: A device has failed during the startup procedure. This does not happen usually, but if it does, you shouldidentify and rectify the problem.301 - Setting path MTU to 68Description: The Path maximum transmission unit (MTU) for a tunnel was set to 68. This message should not appear.301 - Shared key must be at least 20 charactersDescription: This is a configuration error where the user interface (UI) is not generating the configuration file correctly.Someone may have edited the configuration files by hand or a configuration file is corrupted. You shouldmake modifications in the UI, and then activate the new configuration.301 - Source routing was on and is now offDescription: (Microsoft Windows only) This message provides information on the status of the network checkconducted.301 - Spawn failedDescription: Attempts to run a process have failed. The administrator needs to check the parameters to identify theproblem.301 - SRL is not enabled for this clientDescription: You can restrict source addresses from which a user can establish a secure remote login (SRL) session. Inthis case, the user has attempted to connect from an address that has not been configured, so theconnection was terminated.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!