Log messagesWarning messages (300-399)179301 - Cannot understand required keywordDescription: This is a configuration error where the user interface (UI) is not generating the configuration file correctly.Someone may have edited the configuration files by hand or a configuration file is corrupted. You shouldmake modifications in the UI, and then save and reconfigure.301 - Cannot understand required keyword, so group member will not be added to groupDescription: This message indicates an internal software error. Please contact Technical Support by phone or online athttp://www.symantec.com/techsupp/ to report this.301 - Cannot understand required keyword, so group will not be loadedDescription: This is a configuration error where the user interface (UI) is not generating the configuration file correctly.Someone may have edited the configuration files by hand or a configuration file is corrupted. You shouldmake modifications in the UI, and then activate the new configuration.301 - Cannot understand required keyword, so host will not be loadedDescription: This is a configuration error where the user interface (UI) is not generating the configuration file correctly.Someone may have edited the configuration files by hand or a configuration file is corrupted. You shouldmake modifications in the UI, and then activate the new configuration.301 - Cannot understand required keyword, so IKE policy will not be loadedDescription: The configuration file is corrupted. Try reentering the information and then activating the changes.301 - Cannot understand required keyword, so security policy (tunnel) will not be loadedDescription: The configuration file is corrupted. Try reentering the information and then activating the changes.301 - Cannot understand required keyword, so subnet will not be loadedDescription: This is a configuration error where the user interface (UI) is not generating the configuration file correctly.Someone may have edited the configuration files by hand or a configuration file is corrupted. You shouldmake modifications in the UI, and then activate the new configuration.301 - Cannot understand required keyword, so VPN policy will not be loadedDescription: The configuration file is corrupted. Try reentering the information and then activating the changes.301 - Cannot understand required keyword, so workgroup member will not be added to workgroupDescription: This is a configuration error where the user interface (UI) is not generating the configuration file correctly.Someone may have edited the configuration files by hand or a configuration file is corrupted. You shouldmake modifications in the UI, and then activate the new configuration.301 - Channel in half closed (inconsistent) state when freedDescription: An error occurred while disabling the UDP port. The connection is closed and connection information iscleared.301 - Child exited with statusDescription: The forked process has terminated with an error status. The parameters indicate the type of error.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!