12.07.2015 Views

Symantec™ Security Gateways Reference Guide - Sawmill

Symantec™ Security Gateways Reference Guide - Sawmill

Symantec™ Security Gateways Reference Guide - Sawmill

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Log messagesWarning messages (300-399)191301 - Malformed ISAKMP configuration attributesDescription: This message indicates an internal software error. Please contact Technical Support by phone or online athttp://www.symantec.com/techsupp/ to report this.301 - MTU reduction ignoredDescription: At attempt to reduce the frame MTU to a value less than 68 was rejected. This is a configuration error.301 - Need to authenticateDescription: The client needs to authenticate before trying to connect.301 - Net write failedDescription: The secure remote login (SRL) daemon is awaiting the authorization challenge from the client when itreceived a communication error. The session is terminated.301 - No route found to hostDescription: Unable to establish connection to a remote host. You have to establish a route or check the route for theconnection to function properly.301 - No security gateway specified for workgroup member. The entity will be dropped from thegroupDescription: This message is a warning about a bad configuration.301 - No statistics block for usernameDescription: The statistics block for this user (the name is in the resource field) cannot be found and the user is deniedaccess.301 - Not authorized because connection from non-reserved portDescription: This message appears when someone attempts to direct connect on a port that is not open.301 - Out of space. Data truncated and transmission abortedDescription: The HTTP daemon has run out of memory to continue processing this request. If this condition persists,you may need to restart the security gateway.301 - Packet from IP address was blockedDescription: The kernel has blocked a bad packet.301 - Phase 2 ID type of ID_IPV4_ADDR_RANGE is not supportedDescription: Tunnels between a host and subnet are supported, but not between a host and a range of addresses. Subnetentities are normally created to define a range of IP addresses that are permitted by a rule.301 - Range supplied in config.cf for UDP ports is too smallDescription: Check the H.323 configuration for errors. The range is less than 10. Change the values of h323d.udp_lowand h323d.udp_high to valid values. The daemon exits.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!