200 Log messagesWarning messages (300-399)314 - Search order not specified or unrecognized keyword, so host resolution will failDescription: The order of the commands in host.conf has a syntax error.316 - Node ID mismatch - node with IP address has an incorrect node IDDescription: An error has occurred in the cluster, a member of another cluster is communicating to this cluster.317 - Numeric username, so ignoringDescription: The security gateway encounters problems while parsing the rules. The log message provides moreinformation on this problem.317 - Unknown user, so ignoringDescription: The security gateway encounters problems while parsing the rules. The log message provides moreinformation on this problem.321 - Resuming downloads with antivirus comforting not allowedDescription: The protocol REST command cannot be used when comforting is enabled. The command is ignored.321 - Unable to notify process of updated configurationDescription: The SGMI attempts to send a configuration to the security gateway but the process was unable to receive it.The process currently runs with an older configuration.324 - No login prompt from paging serviceDescription: The notify daemon was unable to communicate with the paging service because the paging service did notsend the prompt (“ID=”) within the set time frame.324 - No login prompt from paging serviceDescription: The notify daemon was unable to communicate with the paging service because the paging service did notsend the prompt (“ID=”) within the set time frame.327 - Connection request rejected because the client does not have a unique IP addressDescription: More than one host has the same IP address. The software was unable to compensate since two hosts withidentical addresses are making identical requests at the same time. If the protocol is TCP, the connectionattempt failed. If the protocol is UDP, the packet has been dropped. This has an impact on the connectivity.If you are running the Symantec Client VPN, change the subnet you are using behind your NAT to oneunlikely to be used by someone else, if possible. Network renumbering can sometimes be employed toeliminate non-unique collisions.If you are not running Client VPN, this could be a network configuration problem.327 - Connection request rejected because the server does not have a unique IP addressDescription: More than one host has the same IP address. The software was unable to compensate since two hosts withidentical addresses are making identical requests at the same time. If the protocol is TCP, the connectionattempt failed. If the protocol is UDP, the packet has been dropped. This has an impact on the connectivity.If you are running the Symantec Client VPN, change the subnet you are using behind your NAT to oneunlikely to be used by someone else, if possible. Network renumbering can sometimes be employed toeliminate non-unique collisions.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!