12.07.2015 Views

Symantec™ Security Gateways Reference Guide - Sawmill

Symantec™ Security Gateways Reference Guide - Sawmill

Symantec™ Security Gateways Reference Guide - Sawmill

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Log messagesError messages (400-499)253457 - The line has a network address that includes bits not in subnet maskDescription: The “subnet_map” does not appear to be valid in the hosts file.457 - The line has a subnet mask size out of range (25-31)Description: The “subnet_map” does not appear to be valid in the hosts file.457 - The root server must be specified as a nameDescription: The root server in the hosts file is invalid. The resource parameter indicates the line number that iserroneous.457 - The user authenticated without specifying a domain, and it was not possible to discover theuser's domainDescription: This is a Microsoft Windows domain authentication error. The user name was not specified correctly. Theauthentication failed.457 - This system is not an NT domain memberDescription: This is a Microsoft Windows domain authentication error.457 - Unable to connectDescription: A service was unable to connect to the server.457 - Unable to load entryDescription: Unable to load the ARP table. Check the configuration settings.457 - Unable to pass packet to IPDescription: The logservice (or another process) was unable to open a communication channel with the driver. Thelogservice daemon unable to record kernel log messages. Ensure that the security gateway configuration isset up correctly.457 - Unauthorized NP notification, incorrect portDescription: A request was received to modify the blacklist but the request was received on an improper port. This couldindicate improper configuration of machine accounts, or less likely, a denial of service attempt.457 - Unauthorized NP notification, no entry in remkeysDescription: An unauthorized request was received to modify the blacklist. This could indicate improper configurationof machine accounts, or less likely, a denial of service attempt.457 - Unspecified internal server error while connectingDescription: The HTTP daemon server is unable to connect to a remote gopher server.463 - Failed to get node statusDescription: This message indicates an internal software error. Please contact Technical Support by phone or online athttp://www.symantec.com/techsupp/ to report this.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!