198 Log messagesWarning messages (300-399)304 - License will expireDescription: This message notifies the user that the license of the product has expired. The parameters in the logmessage identify the product. Access the Symantec licensing and registration site at www.symantec.com/certificate to acquire a license file for the product.304 - No active hotfixes were foundDescription: The hotfix utility was instructed to uninstall all hotfixes but the active hotfix list is empty. The instructionis ignored. No user action is necessary.304 - No recent hotfixes were foundDescription: The hotfix utility was instructed to uninstall recent hotfixes but the recent hotfix list is empty. Theinstruction is ignored. No user action is necessary.304 - Specified hotfix is already installed or supersededDescription: The hotfix utility was instructed to install a hotfix that has already been installed or has been supersededby a newer hotfix. The instruction is ignored. No user action is necessary.304 - Specified hotfix is not installed and activeDescription: The hotfix utility was instructed to uninstall a hotfix that has not been installed or has been superseded bya newer hotfix. The instruction is ignored. No user action is necessary. If this hotfix has been supersededby a newer hotfix and the user wants to uninstall it, all superseding hotfixes must be uninstalled first.306 - Overlapping time rangeDescription: The time range for an authenticated connection overlap. Check the time range in the configuration.308 - Cannot lookup hostDescription: The host name cannot be looked up to find its IP address. The system tries to continue without it. Otherdaemons on the security gateway may also be unable to get external name resolution. Verify that theresolver on the security gateway is correctly configured.On UNIX systems, the resolver is set in the /etc/resolv.conf file. On Microsoft Windows NT systems, theresolver is set in the DNS tab, of the TCP/IP protocols section, of the network control panel applet. Fordual-level DNS configurations, the resolver should contain the IP address of the inside DNS server andnothing else. For configurations where DNSd on the security gateway is the sole DNS server for the localdomain, the security gateway's resolver should contain the loopback address 127.0.0.1, and nothing else.Verify that the DNS server on the security gateway is correctly configured.If you are running security gateway’s DNS proxy (DNSd) on the gateway, verify that the DNS forwarderssection is either empty or contains the IP address of a DNS server on the Internet (usually the ISP’s DNSserver).Verify that the Internet router is not filtering packets with a source port of 53. Filtering packets withsource port 53 prevents DNS forwarding, and results in no outside name resolution.309 - Cannot compile regular expression in configuration fileDescription: The HTTP daemon encountered problems while parsing the configured URL patterns.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!