Telemecanique Altivar 56 manual - Northern Industrial

Telemecanique Altivar 56 manual - Northern Industrial

Telemecanique Altivar 56 manual - Northern Industrial

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Bulletin No. 50006-519-01BChapter 5 — ConfigurationDecember 1996 7 → General Configuration MenuReady StateRunning StateAt SpeedThis menu displays all functions that can be assigned to the logic outputs andallows reassignment where possible. Only the outputs not previously assignedfrom the 7.2→Application Function menu can be reassigned here. An arrowindicates a function that is already assigned. Output functions can be assigned tomore than one output.The R1 relay is assigned to the Fault State function and cannot be reassigned.Also, the Drive Thermal Alarm function is only available on drive controllersATV<strong>56</strong>D16 to ATV<strong>56</strong>D79. The menus illustrated above show the procedure forreassigning the logic outputs. The logic output functions are described in thefollowing sections.If drive controller is waiting for a Run command and is not in fault state, logicoutput is high or relay is energized.When a Run command is present, DC injection is not enabled, and there is no faulton the drive controller, logic output is high or relay is energized. If Bypass isenabled, the Sequence Input must also be present for Running State to be high orenergized.At Speed (LOx)Reference10FrequencyFigure 60: At SpeedWhen drive controller is commanded to run above zero speed and OutputFrequency is equal to Frequency Reference input signal, logic output is high orrelay is energized.Terminal/KeypadAuto/ManualCurrent LimitFault StateDrive Thermal AlarmLoss of FollowerWhen drive controller is in Keypad Command, logic output is high or relay isenergized. When in Terminal Command, logic output is low or relay is notenergized.When drive controller is in Auto mode of operation, logic output is high or relay isenergized. When in Manual mode of operation, logic output is low or relay is notenergized.When drive controller reaches current limit value (depending on setting in7.11→Motor Parameters), logic output is high or relay is energized.If drive controller is in fault state, logic output is high or relay is energized. The R1relay, already assigned to Fault State, deenergizes upon fault.When the drive controller has reached the thermal alarm, activated a minimum of60 seconds before a drive controller thermal fault is reached, logic output is highor relay is energized. Available only on drive controllers ATV<strong>56</strong>D16 to ATV<strong>56</strong>D79.If current reference at AI2 falls below 3 mA, logic output is high or relay isenergized. Can be used only if AI2 is set for 4-20 mA or 20-4 mA.© 1996 Square D All Rights Reserved97ηττπ://νιχοντρολσ.χοm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!