31.07.2015 Views

Telemecanique Altivar 56 manual - Northern Industrial

Telemecanique Altivar 56 manual - Northern Industrial

Telemecanique Altivar 56 manual - Northern Industrial

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Chapter 1 — Receiving and InstallationBulletin No. 50006-519-01BTechnical Characteristics December 1996Tables 3 and 4 show the power and current ratings for 230 V drive controllers whenset for variable torque (Table 3) and variable torque, low noise (Table 4).Table 3:Variable Torque Drive Controller Ratings, 208/230 VOutlineDriveControllerPart No.1 ATV<strong>56</strong>U41M2208 V ±10% and 230 V ±15%, 60 Hz ±5%Switching Frequency: ATV<strong>56</strong>U41M2 to D33M2 = 4 kHz, ATV<strong>56</strong>D46M2 = 2 kHzMotorPower208/230 V60 HzInput Line CurrentOutputCurrentMax.TransientCurrent(60 s)TotalDissipatedPower208 V230 V8,800 5,000 22,000AIC AICAIChp A A A A A W1235.710.214.04.98.611.85.810.214.04.07.510.611.711.711.7120140170ATV<strong>56</strong>U72M2 7.5 30.6 25.8 30.6 24.2 26.6 3022ATV<strong>56</strong>U90M2 10 38.8 32.7 38.8 31 34 4143 ATV<strong>56</strong>D12M2 15 54.7 46.2 54.8 47 51 5594 ATV<strong>56</strong>D23M2 20 69.3 58.7 69.4 60 65 77025 84.4 71.5 84.4 75 82 831ATV<strong>56</strong>D33M2 40 124.9 102.7 125.9 116 126 12605 ATV<strong>56</strong>D46M2 50 149.3 122.6 151.1 143 158 1528Table 4:Variable Torque, Low Noise Drive Controller Ratings, 208/230 VOutline208 V ±10% and 230 V ±15%, 60 Hz ±5%Switching Frequency: ATV<strong>56</strong>U41M2 to D33M2 = 10 kHz, ATV<strong>56</strong>D46M2 = 4 kHzDriveControllerPart No.1 ATV<strong>56</strong>U41M223MotorPower208/230 V60 Hz208 V8,800 AICInput Line Current230 V5,000 22,000AICAICOutputCurrentMax.TransientCurrent(60 s)TotalDissipatedPowerhp A A A A A W1235.810.414.35.48.812.06.410.414.34.07.510.611.711.711.7125150181ATV<strong>56</strong>U72M2 5 21.8 18.3 21.8 16.7 18.4 252ATV<strong>56</strong>U90M2 7.5 30.6 25.8 30.7 24.2 26.6 375ATV<strong>56</strong>D12M2 10 38.9 32.8 39.0 31 34 459ATV<strong>56</strong>D16M2 15 55.1 46.5 55.2 47 51 619ATV<strong>56</strong>D23M2 20 70.3 59.6 70.3 60 66 7854ATV<strong>56</strong>D33M2 30 97.2 80.8 97.2 88 97 11275 ATV<strong>56</strong>D46M2 40 124.2 102.0 125.4 115 126 1332SpecificationsTable 5 contains specifications for 460 V and 208/230 V drive controllers.Table 5:SpecificationsInput voltage 460 V ±15% or 208 V ±10% and 230 V ±15%Displacement power factor Approximately 0.96Input frequency47.5 to 63 HzOutput voltageMaximum voltage equal to input line voltage4 © 1996 Square D All Rights Reservedηττπ://νιχοντρολσ.χοm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!