31.07.2015 Views

Telemecanique Altivar 56 manual - Northern Industrial

Telemecanique Altivar 56 manual - Northern Industrial

Telemecanique Altivar 56 manual - Northern Industrial

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ALTIVAR <strong>56</strong> Fan and Pump Drive User’s ManualBulletin No. 50006-519-01BIndex October 1997nominalcurrent 34, 70nominal frequency 70nominal output frequency 34nominal output voltage 34nominal voltage 71normal control 34–35, 37–38, 76NRP 55Ooffset 89calculating 90one bar graph menu 63open transistor <strong>56</strong>open-close switch 139operator controlsAFC-off-bypass switch 142, 146hand-off-auto switch 139, 142, 146speed potentiometer 139, 142, 146optionscompression lug kit 21recess mounting kit 13outputsanalog 23, 26assignment menu 96contactor 39customer supply 23logic 23, 25motor 20phase fault 108phase loss 47, 55OUT PHASE LOSS 47power 20relay 23, 27wiring 17overcurrent 45overheating 36overloadfault 45protection 39relay 36–37, 106overspeed 38, 47, <strong>56</strong>overtemperature 45overtorque 37overvoltage 45PPA/PB terminals 20–21parameter setting menu 58partial factory settings 112parts list 14, 30, 32, 169PCMCIA carddownloading from 113storing to 112phasefault 45, 47loss 47, 55rotation 72PI (proportional-integralerr output 95FB output 95feed back 88, 90FLT ratio 95integrator 95parameters 95ref output 95Regulator 77regulator 88application examples 91–93function compatibility 89using the function 89set point 88–89SP <strong>manual</strong> 88, 94pilot lightsgroup 1 143, 147group 2 139, 143, 147powercircuit W 139–140circuit Y 142, 144–145circuit Z 146–148control 45converter 117fuses 28input line 43LED 19, 44loss fault 101ratings 3–4, 119–121suppliescontrol 20input line 20logic inputs 24logic outputs 25precharge failure 46, <strong>56</strong>preset speeds 77–78preventive maintenance 44processinput 86time out <strong>56</strong>time-out fault 86profile 58, 60, 70–71programmable relay 23RR1/R2 terminals 135, 137R1A/R1B/R1C terminals 23R2A/R2B/R2C terminals 23ramp time 34ratings 3208 V 121230 V 4, 120460 V 3, 119ready state 97RDY 55, 62recess mounting 13reference inputs 23reference signal10 VDC 140, 143, 1474-20 mA 140–141, 144, 146, 149relayscapacitor charge 46fault 23, 27outputs 27overload 36–37programmable 23terminals 23reset after fault 100rev. action 95rev. speed 94reverse direction 99ROM memorytesting 109rotation normalization 72RST(reset fault) 66RUN 55, 62command 139, 142contact 146output command 86running state 97176 © 1996 Square D All Rights Reservedηττπ://νιχοντρολσ.χοm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!