31.07.2015 Views

Telemecanique Altivar 56 manual - Northern Industrial

Telemecanique Altivar 56 manual - Northern Industrial

Telemecanique Altivar 56 manual - Northern Industrial

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Bulletin No. 50006-519-01BDecember 1996Chapter 6 — Class 8839 ALTIVAR <strong>56</strong> Combination DevicesTechnical CharacteristicsTECHNICALCHARACTERISTICSTable 39: Variable Torque Class 8839 Enclosed ATV<strong>56</strong> Drive ControllerRatings, 460 VAC ±10%Switching Frequency: <strong>56</strong>UCG4V_ to <strong>56</strong>UPG4V_ = 4 kHz; <strong>56</strong>UQG4V_ to <strong>56</strong>USG4V_ = 2 kHzControllerPart No.Motor Power Input Line Current [1] Output460 V 5,000 A/Current60 Hz 10,000 A [2] 22,000 A [3]Max.TransientCurrent (60 s)hp A A A A<strong>56</strong>UCG4V_ 1 2.7 3.2 2.1 2.3PowerConverterPart No.<strong>56</strong>UDG4V_ 2 4.7 5.7 3.4 3.8 ATV<strong>56</strong>U41N4U<strong>56</strong>UEG4V_ 3 6.5 8 4.8 5.3<strong>56</strong>UFG4V_ 5 9.8 11.9 7.6 8.4 ATV<strong>56</strong>U54N4U<strong>56</strong>UGG4V_ 7.5 14 17 11 12 ATV<strong>56</strong>U72N4U<strong>56</strong>UHG4V_ 10 17.7 21.4 14 15.4 ATV<strong>56</strong>U90N4U<strong>56</strong>UJG4V_ 15 25.1 30.6 21 23 ATV<strong>56</strong>D12N4U<strong>56</strong>UKG4V_ 20 31.8 38.3 27 30 ATV<strong>56</strong>D16N4U<strong>56</strong>ULG4V_ 25 38.7 47 34 38 ATV<strong>56</strong>D23N4U<strong>56</strong>UMG4V_ 30 44 52.4 40 44<strong>56</strong>UNG4V_ 40 57.1 67.6 52 57ATV<strong>56</strong>D33N4U<strong>56</strong>UPG4V_ 50 68.6 81.2 65 72 ATV<strong>56</strong>D46N4U<strong>56</strong>UQG4V_ 60 86.4* 94.6 77 98 ATV<strong>56</strong>D54N4U<strong>56</strong>URG4V_ 75 106* 116 96 116 ATV<strong>56</strong>D64N4U<strong>56</strong>USG4V_ 100 138* 150 124 144 ATV<strong>56</strong>D79N4U[1] Short-circuit current available at controller input.[2] 10,000 AIC denoted by asterisk (*).[3] For controllers with the Remote Starter Bypass power circuit, the short circuit withstand rating depends on theovercurrent protective device in the user-supplied bypass starter. It cannot exceed 22,000 A.Table 40: Variable Torque, Low Noise Class 8839 Enclosed ATV<strong>56</strong> DriveController Ratings, 460 VAC ±10%Switching Frequency: <strong>56</strong>UCG4L_ to <strong>56</strong>UNG4L_ = 10 kHz; <strong>56</strong>UPG4L_ to <strong>56</strong>URG4L_ = 4 kHzControllerPart No.Motor Power Input Line Current [1] Output460 V 5,000 A/Current60 Hz 10,000 A [2] 22,000 A [3]Max.TransientCurrent (60 s)hp A A A A<strong>56</strong>UCG4L_ 1 2.7 3.2 2.1 2.3PowerConverter PartNo.<strong>56</strong>UDG4L_ 2 4.7 5.7 3.4 3.8 ATV<strong>56</strong>U41N4U<strong>56</strong>UEG4L_ 3 6.5 8 4.8 5.3<strong>56</strong>UFG4L_ 5 9.8 11.9 7.6 8.4 ATV<strong>56</strong>U72N4U<strong>56</strong>UGG4L_ 7.5 13.9 16.7 11 12 ATV<strong>56</strong>U90N4U<strong>56</strong>UHG4L_ 10 17.6 21.4 14 15.4 ATV<strong>56</strong>D12N4U<strong>56</strong>UJG4L_ 15 24.8 29.9 21 23 ATV<strong>56</strong>D16N4U<strong>56</strong>UKG4L_ 20 31.9 38.7 27 30 ATV<strong>56</strong>D23N4U<strong>56</strong>ULG4L_ 25 38.7 47 34 38<strong>56</strong>UMG4L_ 30 44 52.4 40 44ATV<strong>56</strong>D33N4U<strong>56</strong>UNG4L_ 40 57.1 67.6 52 57 ATV<strong>56</strong>D46N4U<strong>56</strong>UPG4L_ 50 68.3 80.8 65 72 ATV<strong>56</strong>D54N4U<strong>56</strong>UQG4L_ 60 86.4* 94.6 77 98 ATV<strong>56</strong>D64N4U<strong>56</strong>URG4L_ 75 106* 116 96 116 ATV<strong>56</strong>D79N4U[1] Short-circuit current available at controller input.[2] 10,000 AIC denoted by asterisk (*).[3] For controllers with the Remote Starter Bypass power circuit, the short circuit withstand rating depends on theovercurrent protective device in the user-supplied bypass starter. It cannot exceed 22,000 A.© 1996 Square D All Rights Reserved119ηττπ://νιχοντρολσ.χοm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!