Telemecanique Altivar 56 manual - Northern Industrial

Telemecanique Altivar 56 manual - Northern Industrial

Telemecanique Altivar 56 manual - Northern Industrial

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Bulletin No. 50006-519-01BDecember 1996Chapter 6 — Class 8839 ALTIVAR <strong>56</strong> Combination DevicesControl Circuit DiagramsNOTES:1 PILOT LIGHT OPTION GROUP 1RED PWR ONGREEN AFC RUNGREEN BYP RUNYELLOW AFC FAULTREMOTE STARTER BYPASS W/ OPTIONSPOWER CIRCUIT Z1415COMAO1AFC+10VAI1910MANUALSPEEDPOT2.5KCONFIGURE CONTROLLER FUNCTIONS:AO2COM2MENU 7.3 LO1 = RUNNING STATEMENU 7.3 LO2 = FAULT STATEPILOT LIGHT OPTION GROUP 2RED PWR ONGREEN AFC RUNGREEN AUTO MODEYELLOW AFC FAULTPLACE JUMPER BETWEEN TB-4 & TB-32PL CLUSTER2AUTOMODEGPL31PL CLUSTERAFC RUNG2AFC FAULTYPL4321COMLO2LO1AI2S11–+1312SHLDAUTO SPEED REF4 - 20 mADC SIGNAL3CONFIGURE CONTROLLER FUNCTIONS:MENU 7.3 LO1 = RUNNING STATEMENU 7.3 LO2 = FAULT STATECONTROL TRANSFORMER SHOWN FOR 460V PRIMARY.FOR 230V PRIMARY, JUMPER H2-H3 IS REMOVEDAND JUMPERS H1-H3 & H2-H4 ARE INSTALLEDFOR 208V PRIMARY, REFER TO DETAIL APL2S1OFFHAND AUTO4+24VLOPFAULTSIGNALR1BR1C28N.C. AFC29 FAULT CONTACT(CLOSES ON FAULT)4DELAY TIMER TR IS CONNECTED ACROSS COIL TERMINALSA1 & A2 ON IC CONTACTOR FOR ALL CONTACTORS EXCEPTTHOSE WITH PART #S LC1FXXX. FOR THESE, TR IS CONNECTEDIN SERIES WITH COIL TERMINAL A1.XX33 32 4IC<strong>56</strong>LI1LI2R1AR2B5FUSES FU7 & FU8 SUPPLIED ONLY ON 50-100HP @ 460 VACOR 30-50HP @ 208/230 VAC.X78LI3LI4RUNNINGSTATER2CR2A30N.O. AFCRUN CONTACT(CLOSES WHEN31 AFC RUNNING)CONFIGURE CONTROLLER FUNCTIONS AS FOLLOWS:AUTO START CONTACT(SUPPLIED BY OTHERS)MENU 1 DAMPING = 100%MENU 6.1 TORQUE TYPE = VARIABLE OR VARIABLE LOW NOISEL1U/T1MENU 6.2 COMMAND TYPE 2-WIRE (MAINTAINED)MENU 7.12 LOW SPEED = 3 HZL2V/T2MENU 7.12 ACCELERATION = 10 SECMENU 7.12 DECELERATION = 10 SECL3W/T3MENU 7.13 CONTROL TYPE = NOLDMENU 7.2 AUTO MANUAL = LI3CL1GNDAUTO RUN INPUT = LI4CL2SPEED REFERENCE 2 = AI2(5)LC(6)FU3(5) IC (6)MENU 7.3 R2 = RUNNING STATE(3)LC(4)FU2(3) IC (4)(1)LC(2)FU1(1) IC (2)USERCONNECTIONSCB(IF USED)ISOLATION CONTACTOR (IC)TBLI4 8+24 4USER SUPPLIEDAUTO START CONTACTL1LI2LI367(ALTERNATE USER SUPPLIEDWIRING WHEN MODD07 IS USED)OFFHAND AUTOFROMPOWERSUPPLYL2L3+10 9AI1 10COM 11SHLD 12AI2 13COM 14AO1 15SPEED POT2.5 kAUTO SPEED REFERENCE–4 - 20 mADC SIGNAL+(INPUT Z=250)– PROGRAMMABLE ANALOG OUTPUT+ (REFER TO USERS MANUAL)FROMREMOTE STARTER5 FU7FU8S1S2S3(1)(3)(5)TCTCTC(2)(4)(6)(1)(3)(5)OLOLOLT1T2T3TOMOTORTSTCSPR (IF USED)R122 FREEZE/FIRE STAT INTERLOCK*23(* REMOVE JUMPER IF USED)24TRANSFER RUN CONTACT25(CLOSES WHEN TC CONTACTOR IS CLOSED)26OPTIONAL SMOKE PURGE RELAY27(120VAC WILL RUN MOTOR AT FULL SPEED)28FAULT CONTACT29(CLOSES ON FAULT)FU5(H1)3460V(H3) (H2)FU6(H4)1TTRANSFER CONTACTOR (TC)208 VAC1-25 hp VT1-25 hp VTLN30-50 hp VT30-40 hp VTLN230 VAC1-40 hp VT1-30 hp VTLN50 hp VT40 hp VTLN460 VAC1-60 hp VT1-60 hp VTLN75-100 hp VT75 hp VTLNTRANSFORMER VA100 VA200 VA300 VAR23031RUN CONTACT(CLOSES WHEN AFC RUNS)(X1)115V(X2)FU4GNDPL CLUSTERPL CLUSTER1R208V TRANSFORMER CONNECTION(H1) 208V (H2)1T115V(X2)(X1)GNDDETAIL A16BYP RUNPL1TSTC 17PWR ONGLCS21 2PL3OFFTRAFC BYPASS 18 SPR 19 TC4IC34 352 SECXXTSSPR2021 IC36TCOPTIONAL SMOKE PURGESPR RELAY SPR (REMOVEJUMPERS BETWEEN 18 & 19, 20 & 21, AND 22 & 23 IF USED)(IF USED)SPROL22 23FREEZE/FIESTATE INTERLOCKS(REMOVE JUMPER BETWEEN TERMINALS 22 & 23IF USED)REF: 52010-475-05Figure 95: Remote Starter Bypass Package “Power Circuit Z” with Options© 1996 Square D All Rights Reserved155ηττπ://νιχοντρολσ.χοm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!