31.07.2015 Views

Telemecanique Altivar 56 manual - Northern Industrial

Telemecanique Altivar 56 manual - Northern Industrial

Telemecanique Altivar 56 manual - Northern Industrial

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Bulletin No. 50006-519-01BChapter 5 — ConfigurationDecember 1996 7 → General Configuration MenuTable 29: Logic Input States for 3 Preset SpeedsInput a Input bLow Speed or Reference 0 0Preset Speed 1 1 0Preset Speed 2 0 1Preset Speed 3 1 1Seven preset speeds can be obtained with the I/O Extension Module. For moreinformation refer to the catalog (document number VD0C06S201_).Speed ReferenceSPEED REFERENCESPEED REF. 1.: AI1SPEED REF. 2 : AI2CLAMP SUM : YES†, & ENT to modifyENTESCAI2 SIGNAL TYPE0-20 mA4-20 mA20-4 mAX-20 mA,X= mAMULTIPLY BY (-1): NOENTNOYESSpeed Reference allows the assignment of the AI1 and AI2 inputs as SpeedReference 1 or Speed Reference 2. Speed Reference also allows you to modify theanalog current input, AI2, for type of signal. The adjustment range is 0-20 mA,4-20 mA, 20-4 mA, or x-20 mA where x can be programmed from 0 to 20 mA inincrements of 0.1 mA. Factory setting for AI2 is 4-20 mA. When Speed Reference isset to x-20 mA, the frequency at which the drive controller will run is determinedas follows:f = ( High Speed – Low Speed) ( Input mA § 20 mA) + Low SpeedWhen the value of AI2 is below x mA, the drive will run at the Low Speed setting.HSPfLSPXmA20mAFigure 48: Speed Reference and Drive Controller FrequencyIf the switch on the control board is set to voltage, AI2 will be a 0-5 V voltage input.Refer to Chapter 2 for location of switch. AI2 in this case must be set on the keypaddisplay for 0-20 mA. The voltage reference input, AI1, cannot be modified. It isfixed as a 0 to 10 VDC input.The two inputs, AI1 and AI2, are summed as a factory default, limited to HighSpeed. However, when Auto/Manual is active the inputs function independentlyand only one is active at a time. It is possible to multiply AI2 by (-1) by selectingYes. In this case, AI2 is subtracted from AI1. If Clamp Sum is set to Yes (factorysetting) and (AI1-AI2) is zero or negative, the drive controller will run at LowSpeed. If Clamp Sum is set to No and (AI1-AI2) is negative, the drive controller willchange direction. See Notes on page 80.© 1996 Square D All Rights Reserved79ηττπ://νιχοντρολσ.χοm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!