Chapter 1 — Receiving and InstallationBulletin No. 50006-519-01BMounting in General Purpose Metal Enclosure December 1996• Verify that the voltage and frequency characteristics of the input line match thedrive controller nameplate rating.• Installation of a disconnect switch between the input line and drive controlleris recommended. Follow national and local codes.• Overcurrent protection is required. Install line power fuses (F1-F3)recommended in Table 11 on page 30 and Table 13 on page 31.• Turn off all power before installing the drive controller. Place a “DO NOTTURN ON” label on the drive controller disconnect. Before proceeding withinstallation, lock the disconnect in the open position.• The ATV<strong>56</strong>U41N4 to ATV<strong>56</strong>D79N4 and ATV<strong>56</strong>U41M2 to ATV<strong>56</strong>D46M2 drivecontrollers may be mounted inside another enclosure to increase the degree ofprotection or size of the enclosure. See “MOUNTING INGENERAL PURPOSE METAL ENCLOSURE” on page 10 and “MOUNTINGIN TYPE 12 (IP54) METAL ENCLOSURE” on page 12.• To improve ventilation, the front cover may be removed when mounting thedrive controller in an enclosure. For ATV<strong>56</strong>U41N4 to D23N4 andATV<strong>56</strong>U41M2 to ATV<strong>56</strong>D16M2 drive controllers, the front cover is removedby first opening the cover, then separating the retaining clips on the cover fromthe side panel. For ATV<strong>56</strong>D33N4 to D79N4 and ATV<strong>56</strong>D23M2 toATV<strong>56</strong>D46M2 drive controllers, the front cover is removed by first opening thecover, then lifting it vertically.• With the front cover removed, the ATV<strong>56</strong>U41N4 to D79N4 and ATV<strong>56</strong>U41M2to ATV<strong>56</strong>D46M2 drive controllers have an IP20 enclosure rating.• The solid state switches of the drive controller power circuit do not providecomplete isolation from the line. Leakage currents and voltages may bepresent at the U/T1, V/T2, and W/T3 terminals of the drive controllerwhenever power is present.MOUNTING INGENERAL PURPOSEMETAL ENCLOSUREVentilationThe ALTIVAR <strong>56</strong> drive controller is a Type 1/IP30 enclosed product. However,certain application considerations may require that the drive controller be installedinside a larger enclosure. If so, observe the following precautions:Forced air cooling is provided on all drive controllers. A fan is located in thebottom of the drive controller (see Figure 6 on page 11) and is protected by aperforated cover. The fan draws in ambient air from underneath or from the frontof the enclosure over the heat sink fins, and expels it vertically from the top of theenclosure. When mounting the drive controller, be sure the air inlets and outletsare not obstructed.• Follow the installation precautions on pages 9 and 10.• Observe minimum clearance distances as indicated in Figure 5 on page 9.• If the enclosure does not provide sufficient free air flow, an enclosureventilation fan is required to exhaust the heat to the enclosure outside ambient.The enclosure fan should have a greater fan flow rate than the drive controllerfan flow rate listed in Table 6 on page 11.• If there is a possibility of condensation, keep the control supply switched onduring periods when the motor is not running or install thermostaticallycontrolled strip heaters.10 © 1996 Square D All Rights Reservedηττπ://νιχοντρολσ.χοm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!