31.07.2015 Views

Telemecanique Altivar 56 manual - Northern Industrial

Telemecanique Altivar 56 manual - Northern Industrial

Telemecanique Altivar 56 manual - Northern Industrial

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Bulletin No. 50006-519-01BDecember 1996Chapter 1 — Receiving and InstallationMounting in Type 12 (IP54) Metal EnclosureUseful heat exchange surface area (S) of the proposed wall-mounted enclosure:• Height: 40 in (1016 mm)• Width: 40 in (1016 mm)• Depth: 20 in (508 mm)front area top area side areaS = ( 40 × 40) + ( 20 × 40) + 2( 40 × 20)= 4000 in 2If the selected enclosure does not provide the required surface area or does notmeet application needs, consider the following:• Use a larger enclosure.• Use one of the recess mounting kits (ATV<strong>56</strong>U41N4 to D23N4 andATV<strong>56</strong>U41M2 to D16M2 drive controllers). Refer to Table 7.• Add a passive heat exchanger to the enclosure.• Add an air conditioning unit to the enclosure.VentilationRecess MountingWhen the drive controller is mounted inside a Type 12 or IP54 enclosure, observethe following ventilation precautions:• Observe minimum clearance distances shown in Figure 5 on page 9.• Follow the installation precautions on pages 9 and 10.• A stirring fan may be necessary to circulate the air inside the enclosure andprevent hot spots in the drive controller and to distribute the heat uniformlyto surfaces used for convection cooling.• If there is a possibility of condensation, keep the control supply switched onduring periods when the motor is not running or install thermostaticallycontrolled strip heaters.To reduce power dissipated in an enclosure, ATV<strong>56</strong>U41N4 to D23N4 andATV<strong>56</strong>U41M2 to D16M2 drive controllers may be recess mounted in a wall of theenclosure, with the heat sink on the outside. This requires a cutout in the enclosureand a recess mounting kit for recess mounting. When this kit is used, the majorityof the drive controller heat load is dissipated outside the enclosure.The power dissipated in the enclosure (P i ) must be dissipated by the availablesurface area of the enclosure. The heat sink assembly, which is mounted outsidethe enclosure, is rated for Type 12/IP54 protection when used with this kit.There are two types of recess mounting kits, the Gasket Kit, which contains onlythe gasket necessary for recess mounting, and the Mounting Adaptor Plate Kitwhich provides mounting plates along with gaskets to allow assembling the drivecontroller to the plates before bolting the assembly into the enclosure. This aids ininstallation and maintenance of the drive controller.© 1996 Square D All Rights Reserved13ηττπ://νιχοντρολσ.χοm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!