31.07.2015 Views

Telemecanique Altivar 56 manual - Northern Industrial

Telemecanique Altivar 56 manual - Northern Industrial

Telemecanique Altivar 56 manual - Northern Industrial

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Bulletin No. 50006-519-01BDecember 1996Chapter 5 — ConfigurationDisplay ModeDISPLAY MODEDrive Controller RunningSPEED REFER.47.2 HzRUNStatus codeWhen the drive controller is running, the Display screen can show one bar graph,two bar graphs, or fourteen items in four tables. Factory setting is one bar graphdisplaying reference frequency. Drive controller status is also displayed in thelower right corner of the screen. Status codes are defined in Table 20. The type andnumber of functions shown can be modified in the 4→Display Configuration menu(page 62) when access level is set to Total Unlock.Drive Controller in FaultStateDISPLAY MODEFAULTAC LINE OVERVOLTAGEFLTStatus codeWhen a fault appears, the drive controller trips, the motor follows theprogrammed fault stop (page 100), and the Display screen shows the fault type.Table 21 lists the faults that the drive controller can display.Table 20: Display Mode Status CodesCode Definition Code DefinitionNLPNo Line Power (control power suppliedseparately)CLI Current LimitRDY Drive Ready DCB DC Injection BrakingRUN Drive Running (at speed) NRP No Run Permissive (LI1 open)Forward Direction BRK BrakingACC AcceleratingDEC DeceleratingFLT FaultFault DesignationIN-PHASE LOSSUNDERVOLTAGEAC-LIN.OVERVOL.DRIVE OVERTEMP.MOT. OVERLOADLOSS FOLLOWEROUT. PHASE LOSSDC-BUS OVERVOL.Table 21: Faults Displayed on Display Mode ScreenDescriptionInput Phase Loss: loss of power or blown fuses. A brief loss of input supplyphase (≤ 200 ms) is not detectedUndervoltage:input voltage ≤ 380 V (60 Hz, 460 V) ATV<strong>56</strong>•••N4 orinput voltage ≤ 170 V ATV<strong>56</strong>•••M2 ortemporary voltage loss (t ≥ 200 ms)AC line overvoltage: input voltage to power supply too highinput voltage ≥ 550 V (60 Hz, 460 V) ATV<strong>56</strong>•••N4 orinput voltage ≥ 270 V ATV<strong>56</strong>•••M2Drive overtemperature: heatsink temperature too highMotor overload: thermal trip because of prolonged overload or running in singlephase on the output, or motor power rating too low for applicationLoss of follower: loss of the 4-20 mA or 20-4 mA reference at AI2 inputLoss of an output phaseDC bus overvoltage/overcurrent due to excessive braking or overhauling load© 1996 Square D All Rights Reserved55ηττπ://νιχοντρολσ.χοm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!