Configuring <strong>HP</strong>OM<br />

Configuring Flexible Management Templates<br />

NOTE<br />

You can replace the variable with $OPC_ALWAYS to specify that<br />

the time condition is always true. To specify that the current primary<br />

manager is always used as the message target server, replace the <br />

variable with $OPC_PRIMARY_MGR.<br />

Syntax <strong>for</strong> Message <strong>Operations</strong> Templates<br />

Use the following syntax <strong>for</strong> message operations templates:<br />

msgoperations ::= MSGOPERATION TIMETEMPLATE<br />

|<br />

MSGOPERATION<br />

| e<br />

msgoperation<br />

::= INSERVICE|SUPPRESS|LOGONLY<br />

Syntax <strong>for</strong> Service Hours and Scheduled Outages Templates<br />

Use the following syntax <strong>for</strong> templates that define service hours and<br />

scheduled outages:<br />

configfile := [TIMETEMPLATES ]<br />

[CONDSTATUSVARS ]<br />

RESPMGRCONFIGS <br />

Syntax <strong>for</strong> the declaration of condition status variables:<br />

statusvarsdef ::= CONDSTATUSVAR<br />

| e<br />

Syntax <strong>for</strong> the Time Template:<br />

timetmpls<br />

timetmpldefs<br />

timezonetype<br />

conditions<br />

timetmplconds 1<br />

timetmplcond<br />

::= TIMETEMPLATE <br />

DESCRIPTION <br />

| e<br />

::= TIMEZONETYPE <br />

TIMEZONEVALUE | e<br />

::= Fix | Local<br />

::= TIMETMPLCONDS | e<br />

::= TIMETMPLCOND <br />

::= [TIMECONDTYPE ] [TIME FROM<br />

1. Outages only.<br />

Chapter 2 107