About <strong>HP</strong>OM Interoperability<br />

Interoperability Between <strong>HP</strong>OM <strong>for</strong> <strong>UNIX</strong> and <strong>HP</strong>OM <strong>for</strong> Windows<br />

MSGTARGETRULECOND<br />

DESCRIPTION "Message that should be<br />

<strong>for</strong>warded to <strong>HP</strong>OM"<br />

MSGTYPE "ForwardToVP"<br />

MSGTARGETMANAGERS<br />

MSGTARGETMANAGER<br />

TIMETEMPLATE "$OPC_ALWAYS"<br />

OPCMGR IP 0.0.0.0 "bigunix"<br />

# Responsible Mgr is the <strong>HP</strong> <strong>Operations</strong> <strong>Manager</strong> <strong>for</strong><br />

Windows Mgr<br />

MSGTARGETRULE<br />

DESCRIPTION "Message <strong>for</strong> the<br />

<strong>HP</strong> <strong>Operations</strong> <strong>Manager</strong> <strong>for</strong> Windows server"<br />

MSGTARGETRULECONDS<br />

MSGTARGETMANAGERS<br />

MSGTARGETMANAGER<br />

TIMETEMPLATE "$OPC_ALWAYS"<br />

OPCMGR IP 0.0.0.0 "bignt"<br />

c. In the template, change the server names bigunix (<strong>HP</strong>OM <strong>for</strong><br />

<strong>UNIX</strong> server) and bignt (<strong>HP</strong>OM <strong>for</strong> Windows server) to the<br />

server names used in your environment.<br />

d. To ensure that your changes are correct, run the <strong>HP</strong>OM <strong>for</strong><br />

<strong>UNIX</strong> template validation tool opcmomchk(1) on the finished<br />

configuration file:<br />

/opt/OV/bin/OpC/opcmomchk <br />

For more in<strong>for</strong>mation about opcmomchk, see the man page<br />

opcmomchk(1).<br />

e. Copy the file you created to the following directory on the <strong>HP</strong>OM<br />

<strong>for</strong> <strong>UNIX</strong> server:<br />

/etc/opt/OV/share/conf/OpC/mgmt_sv/respmgrs<br />

3. Run the tool Switch management server <strong>for</strong> Windows nodes,<br />

located in the <strong>HP</strong>OM <strong>for</strong> Windows management server console under<br />

Tools/OpenView Tools.<br />

IMPORTANT<br />

Be aware that the status of the tool will stay on “starting” if the<br />

switch was successful.<br />

Chapter 5 215