L C L S C O N C E P T U A L D E S I G N R E P O R T<br />

Figure 8.39 An optical ray diagram for imaging of OTR when the sensor is positioned at the focal<br />

plane and image plane. Such imaging provides the OTR angular distribution pattern or<br />

the beam profile, respectively.<br />

8.11.5 Cherenkov Detectors<br />

A series of Cherenkov detectors will be placed at all diagnostics stations between undulator<br />

segments. These devices are similar to those used at the PEP-II project as beam loss monitors<br />

[53]. These devices are quite simple conceptually, involving a small piece of fused silica glass,<br />

which emits Cherenkov radiation when traversed by high energy charged particles. A miniature<br />

photomultiplier tube is used to amplify these small pulses, which are then transmitted to data<br />

acquisition electronics, e.g. a gated integrator followed by a digitizer. To prevent FEL x- rays<br />

from corrupting the bremsstrahlung gamma ray signal, the fused silica pellet is embedded in a<br />

lead-lined housing such that only very high energy photons can penetrate. Refinements to the<br />

PEP-II mechanical design and data acquisition have been carried out recently at the APS [54].<br />

8.11.6 Current Monitoring Toroids<br />

High quality pulsed current monitoring toroids are commercially available, together with<br />

front end electronics, if so desired. It is important to measure the charge entering and exiting the<br />

undulator to provide information for normalization of data sets and to tune for maximum<br />

transport efficiency. It should be straightforward to monitor a nominal 1 nC pulse with a few<br />

percent accuracy shot to shot. Data acquisition is provided.<br />

8-72 ♦ U N D U L A T O R