L C L S C O N C E P T U A L D E S I G N R E P O R T<br />

for an interface to the x-ray beam line.<br />

1.2.3 Undulator. The undulator system provides the magnetic environment for<br />

interaction between the electron beam and an exponentially growing,<br />

coherent x-ray beam. This element includes undulator magnet, vacuum<br />

system, supports, beam diagnostics for the electron and x-ray beams in the<br />

undulator, ancillary magnets, magnetic measurements and fiducializing the<br />

undulator. Computer controls for hardware in the undulator path will be<br />

included in this element.<br />

1.2.4 Installation and Alignment. This element is responsible for installation<br />

of the technical components and their alignment. This element includes the<br />

removal of existing components from the FFTB, installation of the undulator<br />

and dump magnets in the FFTB, the installation of new linac components,<br />

the installation of the injector components (not including the FEL x-ray<br />

optics).<br />

1.3. Photon Beam Handling and Systems. This element includes all equipment<br />

required for manipulation and characterization of the x-ray beam downstream of the<br />

undulator. “Manipulation” includes collimation, attenuation, focusing,<br />

splitting/delaying, slicing/compressing, and monochromatizing. “Characterization”<br />

includes measurement of x-ray beam properties as necessary for commissioning and<br />

operation of the <strong>LCLS</strong>.<br />

1.3.1 X-Ray Transport and Diagnostics. This element includes mechanical<br />

and vacuum systems for the x-ray beam path, shutters, attenuators, x-ray<br />

optics and x-ray diagnostics.<br />

1.3.2 X-Ray Endstation Systems. This element includes the systems necessary<br />

to verify the performance of the x-ray optics and diagnostics and their<br />

suitability for <strong>LCLS</strong> scientific research. It will include laser systems to which<br />

the <strong>LCLS</strong> x-ray pulse must be synchronized in order to carry out many of the<br />

experiments envisioned for this facility. It will also include computer systems<br />

and detectors necessary to collect and analyze data necessary to verify the<br />

performance of the <strong>LCLS</strong>.<br />

1.3.3 Installation and Alignment of Photon Beam Handling Systems.<br />

W O R K B R E A K D O W N S T R U C T U R E ♦ 15-3