28.01.2023 Views

Manual de diseño de Obras Civiles [Diseño por Viento] CFEV08

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

AYUDAS DE DISEÑO

Para 0.0 – 7.5 m:

p

z

= −0. 9 ( 0.

8) ( 1.

0) ( 585.

9)

− ( −117.

2)

= −304.

6 Pa

2

(-31.1kg/m ); o

p

z

= −0. 4(

0.

8) ( 1.

0) ( 585.

9)

− ( −117.

2)

= −70.

3 Pa

(-7.1kg/m

2

)

Para 7.5 – 15.0 m:

p

z

= −0. 5 ( 0.

8) ( 1.

0) ( 585.

9)

− ( −117.

2)

= −117.

2 Pa

2

( -11.9 kg/m ) ; o

p

z

=

0. 0 ( 0.

8) ( 1.

0) ( 585.

9)

− ( −117.

2)

=

117.

2 Pa

( 12.

0 kg/m

2

)

Para 15.0 – 22.5 m:

p

z

= −0. 3 ( 0.

8) ( 1.

0) ( 585.

9)

− ( −117.

2)

= − 23.

4 Pa

(

- 2.4 kg/m

2

) ; o

p

z

=

0. 1(

0.

8) ( 1.

0) ( 585.

9)

− ( −117.

2)

=

164.

1Pa

(16.

8 kg/m

2

)

Para 22.5 – 60.0 m:

p

z

= −0. 2(

0.

8) ( 1.

0) ( 585.

9)

− ( −117.

2)

=

23.

5 Pa

2

( 2.4 kg/m ) ; o

p

z

=

0. 2(

0.

8) ( 1.

0) ( 585.

9)

− ( −117.

2)

= 210.

9 Pa

( 21.

6 kg/m

2

)

Debido a que en este caso se tienen dos coeficientes de presión exterior para cada una

de las distancias horizontales a partir del muro de barlovento, el diseñador tendrá qué

verificar cuál combinación de presiones es la más desfavorable para el diseño de la

cubierta de la estructura principal ante la acción del viento en la dirección normal a las

generatrices.

En las Figura III.13(a) y III.13(b) se muestran las presiones de diseño para la estructura

principal cuando el viento actúa en la dirección normal a las generatrices.

4. III. 25