IE3.5 OPERATING ANOMALIES WITH ELECTRIC RESET..Code Description Solutionb 18 System delivery temperature above 95 °C Check water circulation in the systemb 19 System return temperature above 90 °C Check water circulation in the systemb 24 ∆t between delivery and return above 10 °C after 180 sec. Check main heat exchangerb 25 System delivery temperature increase too fast Check water circulation in the systemb 26 No water Check correct water pressure inside systemb 28 Fan fault (Hall signal missing) Check fanb 29 Fan fault Check fanb 30 Temperature difference between system delivery and return more than 40 °C Check water circulation in the systemb 33 Domestic water fault (short-circuited) Check domestic water probeb 38 Domestic water fault (open) Check domestic water probeb 65 Stand-by for fan start-up Check fumes circuitb 118 Loss of flame signal during burner functioning Check gas and electric power supply presenceE.g. if the display shows these values it means that theappliance has a temperature difference (∆t) between systemdelivery and return of more than 40 °C. “Blocks” aretemporary and the boiler automatically resets when theanomaly disappears.N.B.: maintenance must be performed by a qualified technician (e.g.Immergas Technical Assistance Service).- Smell of gas. Caused by leakage from gas circuit pipes. Check tightness ofgas supply circuit.- Irregular combustion or noisiness. This may be caused by a dirty burner,incorrect combustion parameters, intake-exhaust terminal not correctlyinstalled. Clean the above components and ensure correct installation ofthe terminal, check correct setting of the gas valve (Off-Set setting) andcorrect percentage of CO2 in fumes.- Trap blocked. This may be caused by dirt or combustion products inside.Check, by means of the condensate drain cap, that there are no residualsof material blocking the flow of condensate.by means of the condensate drain (only accessible after having removedthe casing) cap, that there are no residuals of material blocking the flowof condensate.P 30 - Exchanger blocked. This may be caused by the trap being blocked. Check,- Noise due to air in the system. Check opening of the special air valve cap(Fig. 1-25). Ensure that system pressure and expansion tank precharge arewithin the set limits.N.B.: The boiler must be shut down in case of boiler maintenanceinvolving the closing of one or both system on/offcocks (detail 34 fig. -30).101

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!